Publication date: Available online 5 May 2017
Source:Clinical Biochemistry
Author(s): Joyce Matie Kinoshita da Silva-Etto, Rejane Mattar, Cibele Aparecida Villares-Lopes, Sergio Barbosa Marques, Flair José Carrilho
ObjectivesThe stool antigen assay for H. pylori infection diagnosis with monoclonal antibodies is a simple and recommended technique by the Maastricht V/Florence consensus report. Recently, Pylori K-Set K-1219 (Coris Bioconcept Sprl, Belgium) and HP-F23 (Symbiosys, Brazil) have been made commercially available in Brazil. Thus, the aim of this study was to evaluate the diagnostic accuracies of these two rapid stool antigen tests by immunochromatographic assays (index tests) for the clinical practice.Design and methodsA total of 98 patients who underwent upper gastrointestinal endoscopy and 13C-urea breath test entered the study. H. pylori infection status was defined by the combination of the rapid urease test and the 13C-urea breath test (reference standard). Two observers who were aware of H. pylori status performed the reading of index tests. Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals, positive likelihood ratio, negative likelihood ratio and kappa index measure of agreement) were determined.ResultsThe index tests where in perfect agreement with the H. pylori status with kappa values of 0.87 for Pylori K-Set K-1219 and 0.92 for HP-F23. The sensitivity of HP-F23 was 97.9% (IC95%: 87.5–100) and specificity was 93.8% (IC95%; 84–97.2).The positive likelihood ratio was 15.8, and the negative likelihood ratio was 0.02. The Pylori K-Set K-1219 had a sensitivity of 87.7% (IC95%: 74.5–94.9) and a specificity of 100% (IC95%: 91.6–100); the positive likelihood ratio was ∞, and the negative likelihood ratio was 0.1. The test line on the cassette device of HP-F23 was stronger than of the Pylori K-Set K-1219.ConclusionThe HP-F23 test performed better in clinical practice. Nonetheless, the 13C-urea breath test is more reliable technique. Moreover, caution must be paid to the trace or clear pale test line readings that were observed in false positive and false negative results, leading to incorrect management of the patient.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pk0nHa
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objectives Greece is one of the leading tobacco-producing countries in European Union, and every year over 19 000 Greeks die from tobacco-at...
-
Objectives Drug interactions, poor adherence to medication and high-risk sexual behaviour may occur in individuals with HIV using recreation...
-
Introduction Multimorbidity (MM) refers to the coexistence of two or more chronic conditions within one person, where no one condition is co...
-
Objective To describe the prevalence and severity of diabetic retinopathy (DR) and sight-threatening DR (STDR) among Chinese adults with dia...
-
Related Articles Three job stress models and their relationship with musculoskeletal pain in blue- and white-collar workers. J Psycho...
-
Abstract Background Mature T-cell and natural killer (NK)-cell lymphomas compose a heterogeneous group of non-Hodgkin lymphomas, and ext...
-
<span class="paragraphSection"><div class="boxTitle">Abstract</div>Masked hypertension (MHT), defined ...
-
Background Hepatitis B virus (HBV) transmission is known to occur through direct contact with infected blood. There has been some suspicion ...
-
In Rwanda, the prevalence of viral hepatitis (HCV) is poorly understood. The current study investigated the prevalence and risk factors of H...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου