Publication date: Available online 5 May 2017
Source:Clinical Biochemistry
Author(s): Joyce Matie Kinoshita da Silva-Etto, Rejane Mattar, Cibele Aparecida Villares-Lopes, Sergio Barbosa Marques, Flair José Carrilho
ObjectivesThe stool antigen assay for H. pylori infection diagnosis with monoclonal antibodies is a simple and recommended technique by the Maastricht V/Florence consensus report. Recently, Pylori K-Set K-1219 (Coris Bioconcept Sprl, Belgium) and HP-F23 (Symbiosys, Brazil) have been made commercially available in Brazil. Thus, the aim of this study was to evaluate the diagnostic accuracies of these two rapid stool antigen tests by immunochromatographic assays (index tests) for the clinical practice.Design and methodsA total of 98 patients who underwent upper gastrointestinal endoscopy and 13C-urea breath test entered the study. H. pylori infection status was defined by the combination of the rapid urease test and the 13C-urea breath test (reference standard). Two observers who were aware of H. pylori status performed the reading of index tests. Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals, positive likelihood ratio, negative likelihood ratio and kappa index measure of agreement) were determined.ResultsThe index tests where in perfect agreement with the H. pylori status with kappa values of 0.87 for Pylori K-Set K-1219 and 0.92 for HP-F23. The sensitivity of HP-F23 was 97.9% (IC95%: 87.5–100) and specificity was 93.8% (IC95%; 84–97.2).The positive likelihood ratio was 15.8, and the negative likelihood ratio was 0.02. The Pylori K-Set K-1219 had a sensitivity of 87.7% (IC95%: 74.5–94.9) and a specificity of 100% (IC95%: 91.6–100); the positive likelihood ratio was ∞, and the negative likelihood ratio was 0.1. The test line on the cassette device of HP-F23 was stronger than of the Pylori K-Set K-1219.ConclusionThe HP-F23 test performed better in clinical practice. Nonetheless, the 13C-urea breath test is more reliable technique. Moreover, caution must be paid to the trace or clear pale test line readings that were observed in false positive and false negative results, leading to incorrect management of the patient.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pk0nHa
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Bromodomain proteins function as epigenetic readers that recognize acetylated histone tails to facilitate the transcription of t...
-
Objectives To optimise medical students’ early clerkship is a complex task since it is conducted in a context primarily organised to take ca...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
C. Julian Chen'Correspondence information about the author C. Julian ChenEmail the author C. Julian Chen, Donald A. Miller DOI: https://...
-
ACS Nano DOI: 10.1021/acsnano.7b00032 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2lNPpuk via...
-
Abstract Polychlorinated biphenyls (PCBs), a group of 209 congeners that differ in the number and position of chlorines on the biphenyl rin...
-
1 abqls-210rm.html Read the latest Journal of Clinical Neurophysiology - Vol. 37, No. 1, January 2020.eml 2 agx3v-nxz96.html Read the late...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου