Publication date: Available online 11 January 2018
Source:European Journal of Radiology
Author(s): Yoshiharu Ohno, Kota Aoyagi, Qi Chen, Naoki Sugihara, Tae Iwasawa, Fumito Okada, Takatoshi Aoki
PurposeTo directly compare the effect of a reconstruction algorithm on nodule detection capability of the computer-aided detection (CADe) system using standard-dose, reduced-dose and ultra-low dose chest CTs with and without adaptive iterative dose reduction 3D (AIDR 3D).Materials and methodsOur institutional review board approved this study, and written informed consent was obtained from each patient. Standard-, reduced- and ultra-low-dose chest CTs (250 mA, 50 mA and 10 mA) were used to examine 40 patients, 21 males (mean age ± standard deviation: 63.1 ± 11.0 years) and 19 females (mean age, 65.1 ± 12.7 years), and reconstructed as 1 mm-thick sections. Detection of nodule equal to more than 4 mm in dimeter was automatically performed by our proprietary CADe software. The utility of iterative reconstruction method for improving nodule detection capability, sensitivity and false positive rate (/case) of the CADe system using all protocols were compared by means of McNemar's test or signed rank test.ResultsSensitivity (SE: 0.43) and false-positive rate (FPR: 7.88) of ultra-low-dose CT without AIDR 3D was significantly inferior to those of standard-dose CTs (with AIDR 3D: SE, 0.78, p < 0.0001, FPR, 3.05, p < 0.0001; and without AIDR 3D: SE, 0.80, p < 0.0001, FPR: 2.63, p < 0.0001), reduced-dose CTs (with AIDR 3D: SE, 0.81, p<0.0001, FPR, 3.05, p<0.0001; and without AIDR 3D: SE, 0.62, p<0.0001, FPR: 2.95, p<0.0001) and ultra-low-dose CT with AIDR 3D (SE, 0.79, p<0.0001, FPR, 4.88, p = 0.0001).ConclusionThe AIDR 3D has a significant positive effect on nodule detection capability of the CADe system even when radiation dose is reduced.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2DbQzKb
Δευτέρα 15 Ιανουαρίου 2018
Comparison of Computer-Aided Detection (CADe) Capability for Pulmonary Nodules among Standard-, Reduced- and Ultra-Low-Dose CTs with and without Hybrid Type Iterative Reconstruction Technique
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
The new app from IBM will let crowds automatically coordinates mass displays at big sporting events or protests using their smartphone camer...
-
Abstract Objective The objective of this study were to find the annual case trend of inflammatory jawbone diseases and to investigate th...
-
The investigational third-generation nonsteroidal oral selective estrogen receptor degrader RAD1901 was associated with a 23% objective resp...
-
by Patrick P. Lowe, Benedek Gyongyosi, Abhishek Satishchandran, Arvin Iracheta-Vellve, Aditya Ambade, Yeonhee Cho, Karen Kodys, Donna Catala...
-
http://ift.tt/2pCsm4a
-
ACS Nano DOI: 10.1021/acsnano.6b07541 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvA0Lj via...
-
A magnetic Fe3O4/GO composite with potential for rapid solid-liquid separation through a magnetic field was synthesized using GO (graphene o...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2tGBTt3 via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qS0o5m via IFTTT
-
Activation of class I Phosphoinositide 3-kinases (PI3Ks) by mutation or overexpression closely correlates with the development of various hu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου