Publication date: Available online 23 February 2017
Source:Brachytherapy
Author(s): Yongbok Kim, Jason Wei-Yeong Huynh, Victor J. Gonzalez
PurposeTo investigate Axxent (iCAD, Inc., San Jose, CA) electronic brachytherapy balloon deformation and its dosimetric impact because of an external flexible shield (FlexiShield [FS]; iCAD, Inc.).Methods and MaterialsProstheses breast tissue phantom overlaid three spherical balloon applicators to simulate three clinical scenarios depending on minimum skin-to-balloon surface spacing (SS): balloon with SS of 2 cm, 1 cm, and balloon with 1 cm SS and touching the chest wall. Two sets of megavoltage CT (MVCT) scans were obtained with or without FS for 15 different sizes of balloons. For 45 pairs of MVCT scans, balloon deformation was measured in superior–inferior (dSI) dimension on coronal and sagittal planes and anterior–posterior (dAP) and lateral (dLAT) dimensions on the equatorial plane of balloon. SS was also compared. A treatment plan was made on each MVCT scan. Doses at four balloon surface points and skin were compared. Conformity index value was also compared to evaluate three-dimensional dose distribution. Clinically, 20 Gy was prescribed to the surface of balloon.ResultsBalloon deformation was observed with compression in SI and AP dimensions and expansion in lateral dimension. Average SI compression was 0.5 mm. Average dLat - dAP was 2.4 mm, which resulted in elevated point doses at AP dimension by 10.8% of prescribed dose and reduced point doses at lateral dimension by 4.6%. FS decreased SS by 1.8 mm, increasing skin dose by 1.2 Gy, on average. Conformity index value was decreased from 0.922 to 0.908, on average.ConclusionsThis phantom study demonstrates that use of skin shielding during breast intraoperative radiation therapy can cause balloon deformation and SS reduction, resulting in dosimetric changes that are disregarded in current practice.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2mrsQcf
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Publication date: March 2017 Source: Free Radical Biology and Medicine, Volume 104 from #AlexandrosSfakianakis via Alexandros G.Sfak...
-
Dtsch med Wochenschr DOI: 10.1055/s-0043-100054 Hintergrund und Fragestellung Ein etablierter Weg, die optimale Behandlung von Tumorpatien...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Deepak Thapa, Vanita Ahuja, Deepanshu Dhiman Indian Journal of Anaesthesia 2017 61(12):1012-1014 from #AlexandrosSfakianakis via Alexa...
-
Abstract Limited memory size is considered as a major bottleneck in data centers for intelligent urban computing. It is shown that there e...
-
ecancer is supporting #BowelCancerAwarenessMonth https://t.co/opXxCAAxzE from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inore...
-
Linked Article: Maintz et al. Br J Dermatol 2017; 176:481–487 . from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader h...
-
Angelina Jolie’s openness about her diagnosis has undoubtedly raised public awareness of the importance of inherited cancers. Although Desai...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου