The influence of the as-grown zinc oxide nanorods (ZnO NRs) on the fabricated electrochemical sensor for in vitro glucose monitoring were investigated. A direct growth of ZnO NRs was performed on the Si/SiO2/Au electrode, using hydrothermal and sol-gel techniques at low temperatures. The structure, consisting of a Si/SiO2/Au/GOx/Nafion membrane, was considered as a baseline, and it was tested under several applied potential 0.1–0.8 V. The immobilized working electrode, with GOx and a nafion membrane, was characterized amperometrically using a source meter Keithely 2410, and an electrochemical impedance Gamry potentiostat. The sensor exhibited the following: a high sensitivity of ~0.468 mA/cm2 mM, a low detection limit in the order of 166.6 µM, and a fast and sharp response time of around 2 s. The highest sensitivity and the lowest limit of detection were obtained at 0.4 volt, after the growth of ZnO NRs. The highest net sensitivity was obtained after subtracting the sensitivity of the baseline, and it was in the order of 0.315 mA/cm2·mM. The device was tested with a range of glucose concentrations from 1–10 mM, showing a linear line from 3–8 mM, and the device was saturated after exceeding high concentrations of glucose. Such devices can be used for in vitro glucose monitoring, since glucose changes can be accurately detected.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2k5Q1v9
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Recent updating of the World Health Organization (WHO) classification of central nervous system (CNS) tumors in 2016 demonstrates...
-
In our previous work, the dichloromethane-methanol (1:1 v/v) extract, fractions and isolated compounds from Polyscias fulva stem bark showed...
-
Cincinnati.com No fooling; go get your head (and neck) examined for free Cincinnati.com Thursday, get your head examined. UC Health ...
-
Background Agricultural work can expose workers to increased risk of heat strain and volume depletion due to repeated exposures to high ambi...
-
Nursing students' perceptions of a video-based serious game's educational value: A pilot study. Nurse Educ Today. 2017 Dec 28;...
-
Anaphora is a rhetorical term for the repetition of a word or phrase at the beginning of successive clauses or verses. from #AlexandrosSfa...
-
Abstract We introduce a novel diagnostic Visual Voiding Device (VVD), which has the ability to visually document urinary voiding events an...
-
Method combines radiomics with three - compartment breast image analysis of dual - energy mammography (Source: The Doctors Lounge - Oncology...
-
Cone beam computerized tomography (CBCT) has been widely used in dental implanting. However, the local hospitals usually don’t have access t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου