Publication date: August 2018
Source:Journal of Environmental Radioactivity, Volume 188
Author(s): Szymon Guguła, Krzysztof Kozak, Jadwiga Mazur, Dominik Grządziel, Mariusz Mroczek
In this work a hand-held spectrometer InSpector 1000 with NaI (Tl) 2″ x 2″ detector has been adapted to fast in situ gamma-ray spectroscopy. Two specially designed mounting stands with shielding have been built, allowing conducting measurements in different geometries. Three particular geometries (NW, IS50, IS00) have been chosen for efficiency calibration and further study. The first one (NW) is intended for small environmental samples (volume ca 140 cm3) collected on site. IS50 geometry is a typical in situ geometry meant for radioactivity measurements in soil with detector pointed towards the ground. In this geometry the probe is shielded and mounted 50 cm above the soil surface. The new proposed geometry IS00 is designed in the way that the detector is inserted directly into the soil in order to increase the counting efficiency. The methods of efficiency calibration involved using calibration standards (in NW geometry) and the results obtained in previous in situ measurements with InSpector 2000 portable spectrometer with HPGe detector and ISOCS™ Shield Systems, which is routinely used in environmental measurements.NW geometry turned out to be useful for natural radioisotopes concentrations (K-40, U-238 and Th-232), which significantly exceed typical values of those concentrations observed in Poland. Both IS50 and IS00 geometries are applicative for quick (2 h long measurement) evaluation of typical concentrations of K, U and Th in soils. The newly proposed geometry IS00 is superior as it showed lower detection limits and uncertainties as well as its handling was far easier than of IS50. Authors have proven that hand-held spectrometer InSpector 1000, together with mounting stands and shielding, can be successfully used for fast in situ gamma-spectroscopy. Its relatively small weight and good mobility are additional assets. Moreover, detailed procedures for measurements in each geometry have been developed to conduct such analyses properly.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2xs2agy
Δευτέρα 19 Μαρτίου 2018
Fast in situ gamma spectroscopy using hand-held spectrometer with NaI probe
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Background A reported penicillin allergy may compromise receipt of recommended antibiotic prophylaxis intended to prevent surgica...
-
Related Articles Feasibility of Brain Atrophy Measurement in Clinical Routine without Prior Standardization of the MRI Protocol:...
-
Abstract The core mission of the Early Stage Professionals in Molecular Imaging Sciences (ESPMIS) Interest Group is to help young scientist...
-
Rejuvenation Research , Vol. 0, No. 0. from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2EFILxo via I...
-
Letter to the editor of Acta Neurochirurgica: simultaneous pericranial and nasoseptal "double-flap" reconstruction after comb...
-
Adenylyl Cyclase-Associated Protein 1 in the Development of Head and Neck Squamous Cell Carcinomas. Bull Exp Biol Med. 2016 Mar 29; A...
-
Context. Despite improvement in pain management and availability of clinical treatment guidelines, patients in Jordan are still suffering fr...
-
In view of the performance requirements (e.g., ride comfort, road holding, and suspension space limitation) for vehicle suspension systems, ...
-
Ravikiran N Pawar, Sambhunath Banerjee, Subhajit Bramha, Shekhar Krishnan, Arpita Bhattacharya, Vaskar Saha, Anupam Chakrapani, Saurabh Bhav...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου