Author(s): Dominik Grządziel, Krzysztof Kozak, Jadwiga Mazur, Mariusz Mroczek
ISOCS (In Situ Counting Object System) from Canberra is applied in laboratory for creating efficiency calibrations of good quality without using radioactive standards. Besides of typical sample containers used in laboratory, ISOSC system also allows modelling containers and objects of almost any shape and elemental composition.The study was based on gamma spectrometry with HPGe semiconductor detector with electronics and software spectrum analysis GENIE 2000 + ISOCS. Measuring set is equipped with portable shield system with set of collimators ISOCS Shield Systems Model ISOXSHLD from Canberra. This shielding system provides attenuation of gamma background radiation with average value 33 (for gamma energies from 186 keV to 2615.5 keV).The portable shield system can be used for low-background laboratory measurements. For this purpose a measuring vessel of new geometry was constructed: the polystyrene cylinder with a height of 40 mm and a diameter of 70 mm. The efficiency calibration for this container was performed using both ISOCS system and classical calibration standard in the same geometry. In order to verify the correctness of performed calibration procedures, the measurements of radioactive standard CBSS 2 were made. The results of both calibrations were compared with the data from the standard certificate. Satisfactory agreement was achieved. Mean percentage difference between results from ISOCS calibration compared to reference values is 6% for all isotopes activities in CBSS 2 standard.The set of collimators was used to develop efficiency calibration for in situ measurements of the soil surface. Test measurements were carried out at the area of the Institute of Nuclear Physics Polish Academy of Sciences in Kraków, Poland (IFJ PAN). Two measurement methods were compared: in situ and laboratory gamma spectroscopy. The obtained average results (from all 10 measuring points) are consistent within the range of measurement uncertainty.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2yEKwv8
Δευτέρα 19 Μαρτίου 2018
Application of ISOCS system in the laboratory efficiency calibration
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
We Are a Leadership Development Company. Harvard Business Publishing Corporate Learning partners with clients to create world-class leadersh...
-
Learning about your ELL families provides an important foundation for everything else you do at the school. Even basic information about stu...
-
Sample essay. The remainder of this essay writing tutorial is based on a short sample 'divorce essay' (about 1,000 words). To comple...
-
An injection molding plant was in turmoil. Plant management wanted more equipment and plant space in order to meet production demands. But e...
-
The thesis statement is that sentence or two in your text that contains the focus of your essay and tells your reader what the essay is goin...
-
Abstract Urothelial bladder carcinoma (UBC) is the most common among urinary bladder neoplasms. We carried out a preliminary study to dete...
-
The second half of the 20th century has been marked by rapid advances of research methods in real problem solving, with rapid progress of th...
-
We provide excellent essay writing service 24/7. Enjoy proficient essay writing and custom writing services provided by professional academi...
-
Lists about: Best Books Ever, Best Young Adult Books, Best Books of the 20th Century, Best Books of the Decade: 2000s, Best Historical Ficti...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου