ISOCS (In Situ Counting Object System) from Canberra is applied in laboratory for creating efficiency calibrations of good quality without using radioactive standards. Besides of typical sample containers used in laboratory, ISOSC system also allows modelling containers and objects of almost any shape and elemental composition.The study was based on gamma spectrometry with HPGe semiconductor detector with electronics and software spectrum analysis GENIE 2000 + ISOCS. Measuring set is equipped with portable shield system with set of collimators ISOCS Shield Systems Model ISOXSHLD from Canberra. This shielding system provides attenuation of gamma background radiation with average value 33 (for gamma energies from 186 keV to 2615.5 keV).The portable shield system can be used for low-background laboratory measurements. For this purpose a measuring vessel of new geometry was constructed: the polystyrene cylinder with a height of 40 mm and a diameter of 70 mm. The efficiency calibration for this container was performed using both ISOCS system and classical calibration standard in the same geometry. In order to verify the correctness of performed calibration procedures, the measurements of radioactive standard CBSS 2 were made. The results of both calibrations were compared with the data from the standard certificate. Satisfactory agreement was achieved. Mean percentage difference between results from ISOCS calibration compared to reference values is 6% for all isotopes activities in CBSS 2 standard.The set of collimators was used to develop efficiency calibration for in situ measurements of the soil surface. Test measurements were carried out at the area of the Institute of Nuclear Physics Polish Academy of Sciences in Kraków, Poland (IFJ PAN). Two measurement methods were compared: in situ and laboratory gamma spectroscopy. The obtained average results (from all 10 measuring points) are consistent within the range of measurement uncertainty.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2yEKwv8
Δευτέρα 19 Μαρτίου 2018
Application of ISOCS system in the laboratory efficiency calibration
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Greens Blue Flame supplies propane tank installation services and propane delivery in the Houston, TX area. We also offer bulk commercial de...
-
Copyright © 1999-2007 by , Kai Froeb. Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free ...
-
A Vietnam War Timeline [Note: This timeline is an abbreviated version of the more detailed timeline posted on the Public Broadcasting System...
-
Cutaneous squamous cell carcinoma (cSCC) are amongst the most common cancers with metastatic potential. Specific clinical and pathological “...
-
IZE is a professional association dedicated to expanding the educational impact of zoos and aquariums worldwide, to enhance the understandin...
-
1,001 FREE cover letter examples and samples for consultants, career changers, and job hunters. The FIRST and BEST cover letters on the Inte...
-
The National Booster Club Training Council, Providing Guidance, Education, Training and Support from #AlexandrosSfakianakis via Alexandros...
-
Examples of Money Laundering Investigations - Fiscal Year 2015. The following examples of Money Laundering Investigations are written from p...
-
BibMe Free Bibliography & Citation Maker - MLA, APA, Chicago, Harvard from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inor...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου