Consistent vital sign monitoring is critically important for early detection of clinical deterioration of patients in hospital settings. Mostly, nurses routinely measure and document the primary vital signs of all patients 2‐3 times daily to assess their condition. To reduce nurse workload and thereby improve quality of patient care, a smart vital sign monitor named “Vital‐SCOPE” for simultaneous measurement of vital signs was developed. Vital-SCOPE consists of multiple sensors, including a reflective photo sensor, thermopile, and medical radar, to be used in simultaneous pulse rate, respiratory rate, and body temperature monitoring within 10 s. It was tested in laboratory and hospital settings. Bland-Altman and Pearson’s correlation analyses were used to compare the Vital-SCOPE results to those of reference measurements. The mean difference of the respiratory rate between respiratory effort belt and Vital-SCOPE was 0.47 breaths per minute with the 95% limit of agreement ranging from −7.4 to 6.5 breaths per minute. The Pearson’s correlation coefficient was 0.63 (). Moreover, the mean difference of the pulse rate between electrocardiogram and Vital-SCOPE was 3.4 beats per minute with the 95% limit of agreement ranging from −13 to 5.8 beats per minute; the Pearson’s correlation coefficient was 0.91 (), indicating strong linear relationship.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2EsTETA
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Hedgehog signalling pathway orchestrates angiogenesis in triple-negative breast cancers British Journal of Cancer 116, 1425 (23 May 2017). ...
-
Publication date: October 2017 Source: International Journal of Biological Macromolecules, Volume 103 Author(s): Shehwaz Anwar, Hina Youn...
-
Publication date: April 2017 Source: European Journal of Cancer, Volume 75 Author(s): A. Ieni, G. Angelico, P. Zeppa, G. Tuccari fro...
-
BACKGROUND AND PURPOSE: Feasibility of brain atrophy measurement in patients with MS in clinical routine, without prior standardization o...
-
Abstract Background A reported penicillin allergy may compromise receipt of recommended antibiotic prophylaxis intended to prevent surgica...
-
Objective A systematic review and meta-analysis to investigate the impact of electronic nicotine delivery systems (ENDS) and/or electronic n...
-
Publication date: Available online 13 May 2017 Source: Biochimica et Biophysica Acta (BBA) - Gene Regulatory Mechanisms Author(s): Ping Li...
-
Rejuvenation Research , Vol. 0, No. 0. from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2EFILxo via I...
-
Adenylyl Cyclase-Associated Protein 1 in the Development of Head and Neck Squamous Cell Carcinomas. Bull Exp Biol Med. 2016 Mar 29; A...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου