Objectives The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. Methods We performed an experimental phantom study with 4 mediastinal iodine phantoms. Each phantom contained 6 tubes of different iodine concentrations (0, 1.0, 2.5, 5.0, 10.0, and 20.0 mg/mL) diluted in a specific solvent, which was water, 10% amino acid solution, 20% lipid emulsion, or 18% calcium solution, respectively. Mediastinal phantoms were inserted into an anthropomorphic chest phantom and were scanned with 3 different DECT scanners from 3 vendors using 2 radiation dosage settings. Iodine density (IoD) and computed tomography (CT) attenuation at virtual monoenergetic 70-keV images and virtual nonenhanced images were measured for the iodine phantoms. The effects of DECT scanners, solvents, and radiation dosage on the absolute measurement error of IoD and on the CT attenuation profiles were investigated using linear mixed-effects models. Measurement variability range of IoD was also determined. Results Absolute error of IoD was not significantly affected by the DECT systems, kind of solvents, and radiation dosage settings. However, CT attenuation profiles were significantly different among the DECT vendors and simulated body fluids. Measurement variability range of IoD was from −0.6 to 0.4 mg/mL for the true iodine concentration 0 mg/mL. Conclusions Dual-energy CT systems and fluid characteristics did not have a significant effect on the IoD measurement accuracy. A cutoff of IoD for the determination of a truly enhancing lesion on DECT would be 0.4 mg/mL. Received for publication September 27, 2017; and accepted for publication, after revision, November 23, 2017. Conflicts of interest and sources of funding: none declared. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Web site (http://ift.tt/2kq7jVD). Correspondence to: Jin Mo Goo, MD, PhD, Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 110-744, Korea. E-mail: jmgoo@plaza.snu.ac.kr. Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2D6GIFD
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Dtsch med Wochenschr DOI: 10.1055/s-0043-100054 Hintergrund und Fragestellung Ein etablierter Weg, die optimale Behandlung von Tumorpatien...
-
Publication date: March 2017 Source: Free Radical Biology and Medicine, Volume 104 from #AlexandrosSfakianakis via Alexandros G.Sfak...
-
Related Articles Anatomic parameters of the sacral lamina for osteosynthesis in transverse sacral fractures. Surg Radiol Anat....
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5... Medicine by Alexandros G. Sfakianakis,Anapafseos 5... Heralding change: The evolution ...
-
BACKGROUND AND PURPOSE: Dengue is a common arboviral disease, which uncommonly involves the brain. There has been a recent surge in dengu...
-
Purpose. We present a case of a patient with Soemmering ring after cataract surgery and a potential complication that can arise as a result ...
-
Abstract Purpose Investigate in patients with metastatic and/or irresectable colorectal cancer treated with systemic treatment with cape...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου