Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2B6pouC
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
http://ift.tt/2pCsm4a
-
A rare adult case of poststreptococcal acute glomerulonephritis with a retropharyngeal abscess. CEN Case Rep. 2017 Mar 27;: Authors: ...
-
Abstract Objective The objective of this study were to find the annual case trend of inflammatory jawbone diseases and to investigate th...
-
The new app from IBM will let crowds automatically coordinates mass displays at big sporting events or protests using their smartphone camer...
-
The investigational third-generation nonsteroidal oral selective estrogen receptor degrader RAD1901 was associated with a 23% objective resp...
-
by Patrick P. Lowe, Benedek Gyongyosi, Abhishek Satishchandran, Arvin Iracheta-Vellve, Aditya Ambade, Yeonhee Cho, Karen Kodys, Donna Catala...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qS0o5m via IFTTT
-
(Source: The Doctors Lounge - Oncology) from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2QP84WL via IF...
-
Related Articles Corrections. Otolaryngol Head Neck Surg. 2007 Dec;137(6):987 Authors: PMID: 29135374 [PubMed] from #AlexandrosS...
-
Exposure to ionizing radiation (IR) causes severe injuries to the human body, and normal tissue toxicity also limits the further application...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου