Publication date: Available online 11 December 2017
Source:European Journal of Radiology
Author(s): Tilman Hickethier, Jonathan Byrtus, Myriam Hauger, Andra-Iza Iuga, Gregor Pahn, David Maintz, Stefan Haneder, Jonas Doerner
ObjectivesTo investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard.Materials and MethodsA total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET).ResultsMonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART.Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p <0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02).ConclusionMonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2AcuKVz
Δευτέρα 11 Δεκεμβρίου 2017
Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Publication date: March 2017 Source: Free Radical Biology and Medicine, Volume 104 from #AlexandrosSfakianakis via Alexandros G.Sfak...
-
Dtsch med Wochenschr DOI: 10.1055/s-0043-100054 Hintergrund und Fragestellung Ein etablierter Weg, die optimale Behandlung von Tumorpatien...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Deepak Thapa, Vanita Ahuja, Deepanshu Dhiman Indian Journal of Anaesthesia 2017 61(12):1012-1014 from #AlexandrosSfakianakis via Alexa...
-
Abstract Limited memory size is considered as a major bottleneck in data centers for intelligent urban computing. It is shown that there e...
-
ecancer is supporting #BowelCancerAwarenessMonth https://t.co/opXxCAAxzE from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inore...
-
Linked Article: Maintz et al. Br J Dermatol 2017; 176:481–487 . from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader h...
-
Angelina Jolie’s openness about her diagnosis has undoubtedly raised public awareness of the importance of inherited cancers. Although Desai...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου