Publication date: December 2017
Source:European Journal of Radiology, Volume 97
Author(s): Corinne Balleyguier, Julia Arfi-Rouche, Laurent Levy, Patrick R. Toubiana, Franck Cohen-Scali, Alicia Y. Toledano, Bruno Boyer
PurposeEvaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time.Materials and methodsThe CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0–100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive.ResultsAverage AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: −0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0–37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: −0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: ‐0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a −0.014 difference (95% CI for difference: ‐0.079,0.050) and a small 0.025 increase (95% CI for difference: −0.036,0.087) in recall rate in non-cancer cases were observed with CAD.ConclusionsConcurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zQyq1V
Σάββατο 18 Νοεμβρίου 2017
Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD)
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Kenaf is a multipurpose crop, but a lack of genetic information hinders genetic and molecular research. In this study, we aimed t...
-
Spindle cell/pleomorphic lipoma is an uncommonly encountered benign neoplasm that is usually found in the subcutaneous tissues. Rare cases r...
-
As demonstrated by the market reactions to downgrades of various sovereign credit ratings in 2011, the credit rating agencies occupy an impo...
-
Lichtenstein intervention is currently the classic model of the regulated treatment of inguinal hernias by direct local approach. This “tens...
-
HPV vaccine now funded for boys Scoop.co.nz “Most countries who have to date introduced HPV vaccine have focused on the cervical canc...
-
Multi-organ segmentation of the head and neck area: an efficient hierarchical neural networks approach Abstract Purpose In radiation therapy...
-
ORIGINAL ARTICLES Cyclooxygenase-2 and estrogen receptor-β as possible therapeutic targets in desmoid tumors p. 47 Rasha A Khairy DOI :10....
-
Related Articles New alkylresorcinol metabolites in spot urine as biomarkers of whole grain wheat and rye intake in a Swedish middle-a...
-
2016-09-29T05-30-58Z Source: Journal of Applied Pharmaceutical Science Sadhana Nittur Holla, Meena Kumari Kamal Kishore, Mohan Babu Amber...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου