Publication date: December 2017
Source:European Journal of Radiology, Volume 97
Author(s): Corinne Balleyguier, Julia Arfi-Rouche, Laurent Levy, Patrick R. Toubiana, Franck Cohen-Scali, Alicia Y. Toledano, Bruno Boyer
PurposeEvaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time.Materials and methodsThe CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0–100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive.ResultsAverage AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: −0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0–37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: −0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: ‐0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a −0.014 difference (95% CI for difference: ‐0.079,0.050) and a small 0.025 increase (95% CI for difference: −0.036,0.087) in recall rate in non-cancer cases were observed with CAD.ConclusionsConcurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zQyq1V
Σάββατο 18 Νοεμβρίου 2017
Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD)
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Abstract Objective Valid measurement systems recording tooth mobility upon displacement within the subtle range of physiological strains...
-
Consulting to Finance: How to Network, Tell Your Story, Spin Your Resume, and Dominate Your Investment Banking and Private Equity Interviews...
-
Abstract Purpose Pedicle screw malplacement, leading to neurological symptoms, vascular injury, and premature implant loosening, is not ...
-
MRI Characteristics of Primary Tumors and Metastatic Lesions in Molecular Subgroups of Pediatric Medulloblastoma: A Single-Center ...
-
Chromatin-based mechanisms offer therapeutic targets in acute myeloid leukemia (AML) that are of great current interest. In this study, we c...
-
A comparison of the academic performance and intelligence scores of asthmatic and nonasthmatic primary... A comparison of the academic perfo...
-
The Importance of Flexion MRI in Hirayama Disease with Special Reference to Laminodural Space Measurements. AJNR Am J Neuroradio...
Δεν υπάρχουν σχόλια: