We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG) sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2uo7gMu
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Hedgehog signalling pathway orchestrates angiogenesis in triple-negative breast cancers British Journal of Cancer 116, 1425 (23 May 2017). ...
-
Objective A systematic review and meta-analysis to investigate the impact of electronic nicotine delivery systems (ENDS) and/or electronic n...
-
Publication date: April 2017 Source: European Journal of Cancer, Volume 75 Author(s): A. Ieni, G. Angelico, P. Zeppa, G. Tuccari fro...
-
Ecohydrological responses to climate change will exhibit spatial variability and understanding the spatial pattern of ecological impacts is ...
-
IJMS, Vol. 19, Pages 544: Bacterial Heterologous Expression System for Reconstitution of Chloroplast Inner Division Ring and Evaluation of I...
-
Abstract Maternal obesity is associated with large-for-gestational-age (LGA) neonates and programming of obesity-related cardiovascular d...
-
The parotid gland harbors 85% of all salivary gland neoplasms. Though the majority of tumors are benign, complete surgical resection remains...
-
IJMS, Vol. 19, Pages 480: CircSMARCA5 Inhibits Migration of Glioblastoma Multiforme Cells by Regulating a Molecular Axis Involving Splicing ...
-
Publication date: October 2017 Source: International Journal of Biological Macromolecules, Volume 103 Author(s): Shehwaz Anwar, Hina Youn...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου