The objectives of this study were to measure levels of particulate matter (PM) in mechanically ventilated buildings and to improve understanding of filtration requirements to reduce exposure. With the use of an Ultra High Sensitivity Aerosol Spectrometer and an Aerodyne Mass Spectrometer, ultrafine (0.055–0.1 μm) and fine (0.1–0.7 μm) indoor and outdoor PM was measured as a function of time in an office, a university building, and two elementary schools. Indoor particle levels were highly correlated with outdoor levels. Indoor and outdoor number concentrations in Denver were higher than those in Boulder, with the highest number concentrations occurring during summer and fall. The ratio of indoor-to-outdoor (I/O) PM was weakly but positively correlated with the amount of ventilation provided to the indoor environment, did not vary much with particle size (ranged between 0.48 and 0.63 for the entire size range), and was similar for each period of the week (weekend vs. weekday, night vs. day). Regression analyses showed that ultrafine indoor PM baseline concentrations were higher at night from nighttime infiltration. A lag time was observed between outdoor and indoor measurements. Weekday days had the shortest lag time of 11 min, and weekend nighttime lags when the HVAC was not in use were 50 to 148 min. Indoor-outdoor PM concentration plots showed ultrafine PM was more correlated compared to fine, and especially when the HVAC system was on. Finally, AMS data showed that most of the PM was organic, with occasional nitrate events occurring outdoors. During nitrate events, there were less indoor particles detected, indicating a loss of particulate phase nitrate. The results from this study show that improved filtration is warranted in mechanically ventilated buildings, particularly for ultrafine particles, and that nighttime infiltration is significant depending on the building design.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kEiKb3
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
In our previous work, the dichloromethane-methanol (1:1 v/v) extract, fractions and isolated compounds from Polyscias fulva stem bark showed...
-
Abstract Recent updating of the World Health Organization (WHO) classification of central nervous system (CNS) tumors in 2016 demonstrates...
-
Background Agricultural work can expose workers to increased risk of heat strain and volume depletion due to repeated exposures to high ambi...
-
Nursing students' perceptions of a video-based serious game's educational value: A pilot study. Nurse Educ Today. 2017 Dec 28;...
-
Cincinnati.com No fooling; go get your head (and neck) examined for free Cincinnati.com Thursday, get your head examined. UC Health ...
-
Abstract We introduce a novel diagnostic Visual Voiding Device (VVD), which has the ability to visually document urinary voiding events an...
-
Anaphora is a rhetorical term for the repetition of a word or phrase at the beginning of successive clauses or verses. from #AlexandrosSfa...
-
Method combines radiomics with three - compartment breast image analysis of dual - energy mammography (Source: The Doctors Lounge - Oncology...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου