2016-10-27T06-35-17Z
Source: Asian Journal of Medical and Biological Research
Mainasara Abdullah Sulaiman, Dahiru Shafiu Gumel, Umar Zayyanu Usman, Anaja Peter Ocheni, Yakubu Abdulmumini, Rosemary Nwaelugo Adanze and Yeldu Mohammed Haruna.
Reference ranges (RR) or Reference Intervals (RIs) are very important values for accurate interpretation of clinical laboratory test results. Any test result that is not accompanied by a valid RR value is less informative and may not be interpreted correctly. However, reference values of most analytes for Nigerian population are not readily available. The present study aims at establishing reference values of Serum Leptin and C-Peptide for Dutse, Jigawa State. In a cross sectional study, eighty (80) reference individuals were recruited. Serum Leptin and C-Peptide were analysed using ELISA methods. Following an accepted guideline, population specific reference intervals were established for these analytes and found to be 3.13ng/mL to 14.09ng/mL for Leptin and 0.56ng/mL to 5.64ng/mL for C-Peptide, respectively. Populations sharing similar physical and socio-economic characteristics may adapt these intervals if validated and considered suitable for their laboratory methods.
http://ift.tt/2ePVKAD
Πέμπτη 27 Οκτωβρίου 2016
Establishment of reference ranges for Serum Leptin and C-Peptide using enzyme-linked immmunosorbent assay method: a preliminary report
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
The new app from IBM will let crowds automatically coordinates mass displays at big sporting events or protests using their smartphone camer...
-
Abstract Objective The objective of this study were to find the annual case trend of inflammatory jawbone diseases and to investigate th...
-
The investigational third-generation nonsteroidal oral selective estrogen receptor degrader RAD1901 was associated with a 23% objective resp...
-
by Patrick P. Lowe, Benedek Gyongyosi, Abhishek Satishchandran, Arvin Iracheta-Vellve, Aditya Ambade, Yeonhee Cho, Karen Kodys, Donna Catala...
-
http://ift.tt/2pCsm4a
-
ACS Nano DOI: 10.1021/acsnano.6b07541 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvA0Lj via...
-
A magnetic Fe3O4/GO composite with potential for rapid solid-liquid separation through a magnetic field was synthesized using GO (graphene o...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2tGBTt3 via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qS0o5m via IFTTT
-
Activation of class I Phosphoinositide 3-kinases (PI3Ks) by mutation or overexpression closely correlates with the development of various hu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου