The process of thinned antenna array synthesis involves the optimization of a number of mutually conflicting parameters, such as peak sidelobe level, first null beam width, and number of active elements. This necessitates the development of a multiobjective optimization approach which will provide the best compromised solution based on the application at hand. In this paper, a novel multiobjective normal mutated binary cat swarm optimization (MO-NMBCSO) is developed and proposed for the synthesis of thinned planar antenna arrays. Through this method, a high degree of flexibility is introduced to the realm of thinned array design. A Pareto-optimal front containing all the probable designs is obtained in this process. Targeted solutions may be chosen from the Pareto front to satisfy the different requirements demonstrating the superiority of the proposed approach over multiobjective binary particle swarm optimization method (MO-BPSO). A comparative study is carried out to quantify the performance of the two algorithms using two performance metrics.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S4GCfW
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Recent updating of the World Health Organization (WHO) classification of central nervous system (CNS) tumors in 2016 demonstrates...
-
In our previous work, the dichloromethane-methanol (1:1 v/v) extract, fractions and isolated compounds from Polyscias fulva stem bark showed...
-
Background Agricultural work can expose workers to increased risk of heat strain and volume depletion due to repeated exposures to high ambi...
-
Cincinnati.com No fooling; go get your head (and neck) examined for free Cincinnati.com Thursday, get your head examined. UC Health ...
-
Anaphora is a rhetorical term for the repetition of a word or phrase at the beginning of successive clauses or verses. from #AlexandrosSfa...
-
Nursing students' perceptions of a video-based serious game's educational value: A pilot study. Nurse Educ Today. 2017 Dec 28;...
-
Abstract We introduce a novel diagnostic Visual Voiding Device (VVD), which has the ability to visually document urinary voiding events an...
-
Method combines radiomics with three - compartment breast image analysis of dual - energy mammography (Source: The Doctors Lounge - Oncology...
-
Cone beam computerized tomography (CBCT) has been widely used in dental implanting. However, the local hospitals usually don’t have access t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου