Publication date: May–June 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 3
Author(s): Naoki Kinoshita, Hiroshi Oguchi, Toshiki Adachi, Hiroki Shioura, Hirohiko Kimura
BackgroundUncertainty in the calibration of high-energy radiation sources is dependent on user and equipment type.AimWe evaluated the uncertainty in the positioning of a cylindrical chamber at a reference depth for reference dosimetry of high-energy photon beams and the resulting uncertainty in the chamber readings for 6- and 10-MV photon beams. The aim was to investigate major contributions to the positioning uncertainty to reduce the uncertainty in calibration for external photon beam radiotherapy.Materials and methodsThe following phantoms were used: DoseView 1D, WP1D, 1D SCANNER, and QWP-07 as one-dimensional (1D) phantoms for a vertical-beam geometry; GRI-7632 as a phantom for a fixed waterproofing sleeve; and PTW type 41023 and QWP-04 as 1D phantoms for a horizontal-beam geometry. The uncertainties were analyzed as per the Guide to the Expression of Uncertainty in Measurement.ResultsThe positioning and resultant uncertainties in chamber readings ranged from 0.22 to 0.35mm and 0.12–0.25%, respectively, among the phantoms (using a coverage factor k=1 in both cases). The major contributions to positioning uncertainty are: definition of the origin for phantoms among users for the 1D phantoms for a vertical-beam geometry, water level adjustment among users for the phantom for a fixed waterproofing sleeve, phantom window deformation, and non-water material of the window for the 1D phantoms for a horizontal-beam geometry.ConclusionThe positioning and resultant uncertainties in chamber readings exhibited minor differences among the seven phantoms. The major components of these uncertainties differed among the phantom types investigated.
from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2J8dqpg
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Publication date: March 2017 Source: Free Radical Biology and Medicine, Volume 104 from #AlexandrosSfakianakis via Alexandros G.Sfak...
-
Related Articles Anatomic parameters of the sacral lamina for osteosynthesis in transverse sacral fractures. Surg Radiol Anat....
-
Dtsch med Wochenschr DOI: 10.1055/s-0043-100054 Hintergrund und Fragestellung Ein etablierter Weg, die optimale Behandlung von Tumorpatien...
-
BACKGROUND AND PURPOSE: Dengue is a common arboviral disease, which uncommonly involves the brain. There has been a recent surge in dengu...
-
Abstract Limited memory size is considered as a major bottleneck in data centers for intelligent urban computing. It is shown that there e...
-
Abstract Objective Functional magnetic resonance imaging (fMRI) is one of the most advanced techniques to analyze the cerebral effects o...
-
Vol.36 No.6 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1k8FKtW via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου