The aim of this study is the utilization of human medical CT images to quantitatively evaluate two sorts of “error-driven” material algorithms, that is, the isotropic and orthotropic algorithms, for bone remodelling. The bone remodelling simulations were implemented by a combination of the finite element (FE) method and the material algorithms, in which the bone material properties and element axes are determined by both loading amplitudes and daily cycles with different weight factor. The simulation results showed that both algorithms produced realistic distribution in bone amount, when compared with the standard from CT data. Moreover, the simulated L-T ratios (the ratio of longitude modulus to transverse modulus) by the orthotropic algorithm were close to the reported results. This study suggests a role for “error-driven” algorithm in bone material prediction in abnormal mechanical environment and holds promise for optimizing implant design as well as developing countermeasures against bone loss due to weightlessness. Furthermore, the quantified methods used in this study can enhance bone remodelling model by optimizing model parameters to gap the discrepancy between the simulation and real data.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pBpbyU
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Sensory Topography of Oral Structures. JAMA Otolaryngol Head Neck Surg. 2016 Sep 29; Authors: Bearelly S, Cheung SW Abstract Import...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου