Objectives We hypothesize that, compared with filtered back projection (FBP), iterative reconstruction (IR) increases the detected volume of uric acid, which serves as a measure of the sensitivity of the method, and therefore allows examinations with lower radiation exposure. Thus, the aim of our study was to evaluate the role of IR in dual-energy computed tomography (DECT) for gout assessment and volumetry in an ex vivo gout model using an epoxy phantom and a biophantom. Materials and Methods We prepared specimens with different concentrations of monosodium uric acid in ultrasound gel (30%–50%) and inserted them into an epoxy-based phantom and a porcine foreleg. Computed tomography scanning was performed on a 320-row single-source DECT scanner in volume mode with an ascending order of tube currents. Image data sets were reconstructed using FBP and IR with 2 iteration levels (IR1 and IR2). Measurements in regions of interest (ROIs) and volumetric measurements were performed using either fixed parameters for the analysis software (epoxy phantom) or parameters specifically adapted for each data set (porcine phantom). Seven retrospectively identified clinical data sets were used for validation in patients. Rm-ANOVA was used for statistical analysis. No institutional review board approval was required. Results We found no differences in Hounsfield units between the different reconstruction algorithms (P = 0.09 and 0.05 for 80 and 135 kVp, respectively) and the calculated dual-energy gradient (P = 0.27). Filtered back projection detected less uric acid compared with IR (with fixed parameters: 6.0 ± 0.3 cm3 for FBP and 6.1 ± 0.2 for IR1 and IR2; with adapted thresholds: 1.2 ± 0.3 cm3 for FBP and 1.8 ± 0.1 and 2.0 ± 0.1 for IR1 and IR2, respectively). The differences were significant for all measurements (P = 0.0003). Also in the test cases, FBP detected significantly fewer tophi (mean volume, 1.38 ± 2.1 cm3) compared with IR1 (1.86 ± 2.9) and IR2 (2.07 ± 3.1) (P = 0.04). Conclusions Iterative reconstruction has the potential to improve the sensitivity of a DECT scan for gouty tophi, to decrease radiation exposure, or to combine both options.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2k8egqv
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Dtsch med Wochenschr DOI: 10.1055/s-0043-100054 Hintergrund und Fragestellung Ein etablierter Weg, die optimale Behandlung von Tumorpatien...
-
Publication date: March 2017 Source: Free Radical Biology and Medicine, Volume 104 from #AlexandrosSfakianakis via Alexandros G.Sfak...
-
Related Articles Anatomic parameters of the sacral lamina for osteosynthesis in transverse sacral fractures. Surg Radiol Anat....
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5... Medicine by Alexandros G. Sfakianakis,Anapafseos 5... Heralding change: The evolution ...
-
BACKGROUND AND PURPOSE: Dengue is a common arboviral disease, which uncommonly involves the brain. There has been a recent surge in dengu...
-
Purpose. We present a case of a patient with Soemmering ring after cataract surgery and a potential complication that can arise as a result ...
-
Abstract Purpose Investigate in patients with metastatic and/or irresectable colorectal cancer treated with systemic treatment with cape...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου