Chloride ions attack is the main factor leading to the degradation of concrete durability, while the diffusion process would be significantly aggravated under the dynamic flexural loading and dry-wet cycles. In this paper, the influence coefficients of dynamic flexural loading on chloride/water diffusion coefficients were established, based on the relationship between the dynamic flexural loading and the chloride ions diffusion coefficient of concrete. Based on the model of chloride ions transporting in dry-wet cycle environment, the transport model of chloride ions in concrete under the dynamic flexural loading and dry-wet cycles was established. The effects of different factors on the chloride ions transport law in concrete were analyzed through laboratory test. The results showed that the model was in good agreement with the experimental results. The theory and assumptions proposed applied in the model of chloride ions transport in concrete under the dynamic flexural loading and dry-wet cycles had certain rationality and scientificity.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2l6bHG1
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Rejuvenation Research , Vol. 0, No. 0. from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2EFILxo via I...
-
Letter to the editor of Acta Neurochirurgica: simultaneous pericranial and nasoseptal "double-flap" reconstruction after comb...
-
Abstract The core mission of the Early Stage Professionals in Molecular Imaging Sciences (ESPMIS) Interest Group is to help young scientist...
-
Adenylyl Cyclase-Associated Protein 1 in the Development of Head and Neck Squamous Cell Carcinomas. Bull Exp Biol Med. 2016 Mar 29; A...
-
Abstract Background A reported penicillin allergy may compromise receipt of recommended antibiotic prophylaxis intended to prevent surgica...
-
In view of the performance requirements (e.g., ride comfort, road holding, and suspension space limitation) for vehicle suspension systems, ...
-
Related Articles Feasibility of Brain Atrophy Measurement in Clinical Routine without Prior Standardization of the MRI Protocol:...
-
Purpose: This phase I study aimed to determine the recommended dose (RD), safety profile, and feasibility of a procedure combining intratum...
-
BACKGROUND AND PURPOSE: Feasibility of brain atrophy measurement in patients with MS in clinical routine, without prior standardization o...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου