Publication date: Available online 2 November 2017
Source:Journal of Environmental Radioactivity
Author(s): Jácint Jónás, János Somlai, Anita Csordás, Edit Tóth-Bodrogi, Tibor Kovács
In petroleum engineering, the produced drilling mud sometimes contains elevated amounts of natural radioactivity. In this study, a remediated Hungarian drilling mud depository was investigated from a radiological perspective. The depository was monitored before and after a clay layer was applied as covering.In this study, the ambient dose equivalent rate H*(10) of the depository has been measured by a Scintillator Probe (6150AD-b Dose Rate Meter). Outdoor radon concentration, radon concentration in soil gas, and in situ field radon exhalation measurements were carried out using a pulse-type ionization chamber (AlphaGUARD radon monitor). Soil gas permeability (k) measurements were carried out using the permeameter (RADON-JOK) in situ device. Geogenic radon potentials were calculated. The radionuclide content of the drilling mud and cover layer sample has been determined with an HPGe gamma-spectrometer. The gamma dose rate was estimated from the measured radionuclide concentrations and the results were compared with the measured ambient dose equivalent rate.Based on the measured results before and after covering, the ambient dose equivalent rates were 76 (67–85) nSv/h before and 86 (83–89) nSv/h after covering, radon exhalation was 9 (6–12) mBq/m2s before and 14 (5–28) mBq/m2s after covering, the outdoor radon concentrations were 11 (9–16) before and 13 (10–22) Bq/m3after covering and the soil gas radon concentrations were 6 (3–8) before and 24 (14–40) kBq/m3 after covering. Soil gas permeability measurements were 1E-11 (7E-12-1E-11) and 1E-12 (5E-13-1E-12) m2 and the calculated geogenic radon potential values were 6 (3–8) and 12 (6–21) before and after the covering. The main radionuclide concentrations of the drilling mud were CU-238 12 (10–15) Bq/kg, CRa-226 31 (18–40) Bq/kg, CTh-232 35 (33–39) Bq/kg and CK-40 502 (356–673) Bq/kg. The same radionuclide concentrations in the clay were CU-238 31 (29–34) Bq/kg, CRa-226 45 (40–51) Bq/kg, CTh-232 58 (55–60) Bq/kg and CK-40 651 (620–671) Bq/kg.According to our results, the drilling mud depository exhibits no radiological risk from any radiological aspects (radon, radon exhalation, gamma dose, etc.); therefore, long term monitoring activity is not necessary from the radiological point of view.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2Ajwo8k
Παρασκευή 3 Νοεμβρίου 2017
Radiological survey of the covered and uncovered drilling mud depository
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
A two-arm multicenter phase II trial of one cycle chemoselection split-dose docetaxel, cisplatin and 5-fluorouracil (TPF) induction che...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jCvX3K via IFTTT
-
Dental implants are now broadly used to replace missing teeth, and the presence of infectious complications is rising. Dental implant therap...
-
Indications and extent of central neck dissection for papillary thyroid cancer: An American Head and Neck Society Consensus Statement. ...
-
Abstract Purpose Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important consideration...
-
Abstract Purpose of Review Our goal is to summarize the airway disease literature since September 11, 2001 (9/11), focusing on studies pub...
-
Treatment effectiveness holds considerable importance in the association between service quality and satisfaction in medical service studies...
-
Therapeutic agents designed to stimulate the immune system are now cornerstones in the treatment of metastatic melanoma. These drugs promote...
-
Coenzyme Q (CoQ) is a key component of the mitochondrial respiratory chain, but it also has several other functions in the cellular metaboli...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου