Publication date: Available online 22 July 2017
Source:Journal of Biomechanics
Author(s): Sarah Junaid, Sanjay Sanghavi, Carolyn Anglin, Anthony Bull, Roger Emery, Andrew A. Amis, Ulrich Hansen
Many commercial cemented glenoid components claim superior fixation designs and increased survivability. However, both research and clinical studies have shown conflicting results and it is unclear whether these design variations do improve loosening rates. Part of the difficulty in investigating fixation failure is the inability to directly observe the fixation interface, a problem addressed in this study by using a novel experimental set-up.Cyclic loading-displacement tests were carried out on 60 custom-made glenoid prostheses implanted into a bone substitute. Design parameters investigated included treatment of the fixation surface of the component resulting in different levels of back-surface roughness, flat-back versus curved-back, keel versus peg and more versus less conforming implants. Visually-observed failure and ASTM-recommended rim-displacements were recorded throughout testing to investigate fixation failure and if rim displacement is an appropriate measure of loosening.Roughening the implant back (Ra > 3 µm) improved resistance to failure (P < 0.005) by an order of magnitude with the rough and smooth groups failing at 8712 ± 5584 cycles (mean ± SD) and 1080 ± 1197 cycles, respectively. All other design parameters had no statistically significant effect on the number of cycles to failure. All implants failed inferiorly and 95 % (57/60) at the implant/cement interface. Rim-displacement correlated with visually observed failure.The most important effect was that of roughening the implant, which strengthened the polyethylene-cement interface. Rim-displacement can be used as an indicator of fixation failure, but the sensitivity was insufficient to capture subtle effects.Level of Evidence: Basic Science Study, Biomechanical Analysis.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2uNgORW
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-...
-
Immunotherapy for metastatic melanoma has a decades-long history, and the relatively recent use of checkpoint inhibitors has revolutionized...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2juls25 via IFTTT
-
by Qi Quan, Lei Hong, Biao Chang, Ruoxi Liu, Yun Zhu, Jiang Peng, Qing Zhao, Shibi Lu Purpose The purpose of this study was to simulate and...
-
ACS Nano DOI: 10.1021/acsnano.6b08387 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jIA5i2 via...
-
A critical step in cellular-trafficking pathways is the budding of membranes by protein coats, which recent experiments have demonstrated ca...
-
by Mark A. Valasek, Irene Thung, Esha Gollapalle, Alexey A. Hodkoff, Kaitlyn J. Kelly, Joel M. Baumgartner, Vera Vavinskaya, Grace Y. Lin, A...
-
The secondary channel (SC) of multisubunit RNA polymerases (RNAPs) allows access to the active site and is a nexus for the regulation of tra...
-
A phase 1 dose-escalation and expansion study of binimetinib (MEK162), a potent and selective oral MEK1/2 inhibitor British Journal of Canc...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου