Publication date: Available online 3 May 2017
Source:Journal of Dairy Science
Author(s): M. Iwersen, A. Thiel, D. Süss, D. Klein-Jöbstl, K. Wagener, M. Drillich
The primary objective of this study was to evaluate the repeatability of measurements of β-hydroxybutyrate (BHB) concentrations in capillary blood obtained from minimal-invasive puncturing of different sites at the external vulva skin of dairy cows. A total of 240 multiparous cows sampled once within 21 d in milk were enrolled in the study. Capillary blood samples were obtained from the right and left labium of the external vulva skin and additionally from a site close to the first puncture. Samples were analyzed by using an electronic hand-held device [FreeStyle Precison Neo (FSP-Neo), Abbott GmbH & Co., Wiesbaden, Germany)]. Additionally, samples from a coccygeal vessel were analyzed as reference in a laboratory. Mean deviations (± standard deviation) between the 3 capillary sampling sites ranged from 0.01 ± 0.14 (left vs. right labium) to 0.02 ± 0.13 mmol/L (left or right labium vs. additional site). The BHB concentrations in capillary blood compared with the reference showed a mean deviation of 0.14 ± 0.18 mmol/L. The Spearman correlation coefficient between BHB concentrations in capillary blood and coccygeal blood was 85.4%. Mixed model analyses showed no significant effect of sampling site or squeezing the skin during sampling procedures on the differences toward the reference. Based on laboratory BHB concentrations of ≥1.2 and ≥1.4 mmol/L, respectively, the prevalence of hyperketonemia was 10.4 (n = 25) and 5.0% (n = 12). Thresholds to detect hyperketonemia with the FSP-Neo were optimized by receiver operating characteristic analyses. Based on a laboratory BHB concentration of ≥1.2 mmol/L thresholds were determined as 1.1 (left labium, 2nd puncture) and 1.0 mmol/L (right labium), with sensitivities between 94 and 99% and specificities between 89 and 97%. Based on a serum BHB concentration of 1.4 mmol/L, receiver operating characteristic analyses resulted in optimized cutoffs of 1.4 mmol/L for all sampling sites at the vulva, with sensitivities of 100% and specificities between 96 and 99%. In conclusion, vulvar capillary blood is suitable for accurate measuring of BHB concentrations by using the FSP-Neo. After adjusting the thresholds, the FSP-Neo provides very good test characteristics independent of the capillary sampling site or squeezing the skin and allows a practical and reliable screening tool for dairy cows.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pKl8yH
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
CBN News Cancer Took Most of His Tongue, but This Pastor Is Still Singing ... CBN News A youth pastor in San Diego, California is not ...
-
Abstract Objective To evaluate Chinese medicine (CM) formula Bazheng Powder (八正散) as an alternative therapeutic option for female patients...
-
Audiol Neurotol 2016;21:I-VI from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pSmIj1 via IFTTT
-
Related Articles Screening for Atrial Fibrillation using Economical and accurate TechnologY (SAFETY)-a pilot study. BMJ Open. 2017 Ja...
-
Abstract Soil conditioners can be used to compensate for the insufficient soil nutrition and organic matter (OM) of arable soils. However, ...
-
Micro- and nanoparticles of NiSb2O6 were synthesized by the microwave-assisted colloidal method. Nickel nitrate, antimony chloride, ethylene...
-
Indian Journal of Anaesthesia 2018 62(2):157-157 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2...
-
Abstract This article presents the development and experimental validation of a methodology to reduce the risk of thermal injury to the fa...
-
To evaluate the effect of Recurrence Score® results (RS; Oncotype DX® multigene assay ODX) on treatment recommendations by Swiss multidiscip...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου