Dead reckoning is an important aspect of estimating the instantaneous position of a mobile robot. An inertial measurement unit (IMU) is generally used for dead reckoning because it measures triaxis acceleration and triaxis angular velocities in order to estimate the position of the mobile robot. Positioning with inertial data is reasonable for a short period of time. However, the velocity, position, and attitude errors increase over time. Much research has been conducted in ways to reduce these errors. To position a mobile robot, an absolute positioning method can be combined with dead reckoning. The performance of a combined positioning method can be improved based on improvement in dead reckoning. In this paper, an ultrasonic anemometer is used to improve the performance of dead reckoning when indoors. A new approach to the equation of an ultrasonic anemometer is proposed. The ultrasonic anemometer prevents divergence of the mobile robot’s velocity. To position a mobile robot indoors, the ultrasonic anemometer measures the relative movement of air while the robot moves through static air. Velocity data from the ultrasonic anemometer and the acceleration and angular velocity data from the IMU are combined via Kalman filter. Finally we show that the proposed method has the performance with a positioning method using encoders on a good floor condition.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pzzbHC
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Purpose: The MHC-unrestricted activity of cytokine-induced killer (CIK) cells against chemo-surviving melanoma cancer stem cells (mCSC) was...
-
Induced overexpression of CD44 associated with resistance to apoptosis on DNA damage response in human head and neck squamous cell carc...
-
Current treatments for generalized pustular psoriasis are unsatisfactory. We applied recently-developed techniques for transcriptomic analys...
-
Downregulation of mouse CCR3 by lentiviral shRNA inhibits proliferation and induces apoptosis of mouse eosinophils. Mol Med Rep. 2016 ...
-
Vol.20 No.1 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2seUCMY via IFTTT
-
A randomised controlled trial comparing transnasal humidified rapid insufflation ventilatory exchange (THRIVE) pre-oxygenation with fac...
-
Abstract This paper addresses the hybrid consensus-based formation keeping problem for nonholonomic mobile robots in the presence of a nov...
-
The influence of different types of brackets and efficacy of two chlorhexidine mouthwashes on oral hygiene and the incidence of white s...
-
Robert Schumann regnes som en av de store romantiske komponistene, særlig anerkjent er hans klaver- og kammermusikk. Han startet på utdanni...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου