Purpose. Medial meniscal extrusion (MME) has attracted attention as an index of knee pain in conjunction with clinical symptoms that could be more useful than the diagnosis of knee osteoarthritis on X-ray. However, the size of MME that would cause knee pain has not been clarified. The aim of the present study was to investigate the cut-off value of MME for knee pain. Methods. A total of 318 knees were evaluated. The presence of current or past knee pain was confirmed by interview. Next, MME was measured using vertical sonographic images of the medial joint spaces during weightbearing. Results. Overall, 71 knees were painful (P-group), and 247 knees were not (N-group). MME was 5.9 ± 1.8 mm in the P-group and 2.9 ± 1.5 mm in the N-group (). Analysis of the receiver operating characteristic curve showed that the cut-off value of MME for knee pain was 4.3 mm, with sensitivity of 0.8451 and specificity of 0.8502. In addition, 64% of knees without pain cases at the time of examination whose MME exceeded this cut-off value had past knee pain. Conclusions. The sensitivity and specificity of MME for knee pain were very high with a cut-off value of 4.3 mm.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pppZCT
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
The new app from IBM will let crowds automatically coordinates mass displays at big sporting events or protests using their smartphone camer...
-
Abstract Objective The objective of this study were to find the annual case trend of inflammatory jawbone diseases and to investigate th...
-
The investigational third-generation nonsteroidal oral selective estrogen receptor degrader RAD1901 was associated with a 23% objective resp...
-
by Patrick P. Lowe, Benedek Gyongyosi, Abhishek Satishchandran, Arvin Iracheta-Vellve, Aditya Ambade, Yeonhee Cho, Karen Kodys, Donna Catala...
-
http://ift.tt/2pCsm4a
-
ACS Nano DOI: 10.1021/acsnano.6b07541 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvA0Lj via...
-
A magnetic Fe3O4/GO composite with potential for rapid solid-liquid separation through a magnetic field was synthesized using GO (graphene o...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2tGBTt3 via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qS0o5m via IFTTT
-
Activation of class I Phosphoinositide 3-kinases (PI3Ks) by mutation or overexpression closely correlates with the development of various hu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου