Bikramjit Das, Arijit Samanta, Subhro Mitra, Shahin Nikhat Jamil
Indian Journal of Anaesthesia 2017 61(4):326-331
Background and Aims: The Airtraq™ optical laryngoscope is the only marketed videolaryngoscope for paediatric patients besides the fibre-optic bronchoscope. We hypothesized that intubation would be easier with Airtraq™ compared to Miller blade. Hence, we compared Airtraq™ with the Miller laryngoscope as intubation devices in paediatric patients. Methods: This prospective, randomized study was conducted in a tertiary care teaching hospital. Sixty children belonging to American Society of Anesthesiologists' Grade I–II, aged 2–10 years, posted for routine surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Miller (n = 30) or Airtraq™ (n = 30) laryngoscope. The primary outcome measure was time of intubation. We also measured ease of intubation, number of attempts, percentage of glottic opening score (POGO), haemodynamic changes and airway trauma. Student t test was used to analyse parametric data. Results: Intubation time was comparable between Miller's laryngoscope (15.13 ± 1.33s) compared to Airtraq™ (11.53 ± 0.49 s) (P = 0.29) The number of first and second attempts at intubation were 25 and 5 for the Miller laryngoscope and 29 and 1 for the Airtraq™. Median visual analogue score (VAS) for ease of intubation was 5 in Miller group compared to 3 in Airtraq™ group. The median POGO score was 75 in the Miller group and 100 in the Airtraq™ group (P = 0.01). Haemodynamic changes were maximum and most significant immediately and 1 min after intubation. Airway trauma occurred in three patients (9.09%) in Miller group and one patient (3.33%) in Airtraq™ group. Conclusion: The Airtraq™ reduced the difficulty of tracheal intubation and degree of haemodynamic stimulation compared to the Miller laryngoscope in paediatric patients.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nYVxxo
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Hedgehog signalling pathway orchestrates angiogenesis in triple-negative breast cancers British Journal of Cancer 116, 1425 (23 May 2017). ...
-
Publication date: April 2017 Source: European Journal of Cancer, Volume 75 Author(s): A. Ieni, G. Angelico, P. Zeppa, G. Tuccari fro...
-
BACKGROUND AND PURPOSE: Feasibility of brain atrophy measurement in patients with MS in clinical routine, without prior standardization o...
-
Objective A systematic review and meta-analysis to investigate the impact of electronic nicotine delivery systems (ENDS) and/or electronic n...
-
Publication date: October 2017 Source: International Journal of Biological Macromolecules, Volume 103 Author(s): Shehwaz Anwar, Hina Youn...
-
Publication date: Available online 13 May 2017 Source: Biochimica et Biophysica Acta (BBA) - Gene Regulatory Mechanisms Author(s): Ping Li...
-
Related Articles Characteristic MR Imaging Findings of the Neonatal Brain in RASopathies. AJNR Am J Neuroradiol. 2018 Apr 05;:...
-
Abstract Abnormal accumulation of alpha-synuclein (αsyn) is a pathological hallmark of Lewy body related disorders such as Parkinson's...
-
IJMS, Vol. 19, Pages 570: Alteration of Epigenetic Regulation by Long Noncoding RNAs in Cancer International Journal of Molecular Sciences ...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου