Publication date: Available online 7 January 2017
Source:Clinical Biochemistry
Author(s): Brittany N. Goldstein, Jordan Wesler, Amy S. Nowacki, Edmunds Reineks, Marvin R. Natowicz
An assessment of blood ammonia concentration is common medical practice in the evaluation of an individual with an unexplained mental status change or coma. The determination of a blood ammonia level is most commonly done using a glutamate dehydrogenase (GLDH)-based assay, although there are many potential sources of artifact and the literature is inconsistent regarding key preanalytic issues. Using a GLDH-based assay, we first investigated matrix effects using three anticoagulants: heparin, EDTA and oxalate. Heparin-anticoagulated plasma was substantially less precise than EDTA- and oxalate-anticoagulated plasma. Oxalate-anticoagulated plasma showed a greater baseline of apparent ammonia than either heparin- or EDTA-derived plasma, presumably due to interferants. We then evaluated the stability of EDTA-anticoagulated plasma for assessment of ammonia when stored at 4°C, −14°C or −70°C. There was a linear increase of ammonia with storage at both 4°C and −14°C. Plasma kept at −70°C for up to three weeks showed no change in measured ammonia relative to the baseline determination. This work clarifies preanalytic conditions for which a precise determination of ammonia can be accomplished using a GLDH-based assay.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2iPA4Ij
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
http://ift.tt/2pCsm4a
-
A rare adult case of poststreptococcal acute glomerulonephritis with a retropharyngeal abscess. CEN Case Rep. 2017 Mar 27;: Authors: ...
-
Abstract Objective The objective of this study were to find the annual case trend of inflammatory jawbone diseases and to investigate th...
-
The new app from IBM will let crowds automatically coordinates mass displays at big sporting events or protests using their smartphone camer...
-
The investigational third-generation nonsteroidal oral selective estrogen receptor degrader RAD1901 was associated with a 23% objective resp...
-
by Patrick P. Lowe, Benedek Gyongyosi, Abhishek Satishchandran, Arvin Iracheta-Vellve, Aditya Ambade, Yeonhee Cho, Karen Kodys, Donna Catala...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qS0o5m via IFTTT
-
(Source: The Doctors Lounge - Oncology) from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2QP84WL via IF...
-
Related Articles Corrections. Otolaryngol Head Neck Surg. 2007 Dec;137(6):987 Authors: PMID: 29135374 [PubMed] from #AlexandrosS...
-
Exposure to ionizing radiation (IR) causes severe injuries to the human body, and normal tissue toxicity also limits the further application...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου