Fiber Bragg Gratings (FBGs) are among the most popular optical fiber sensors. FBGs are well suited for direct detection of temperature and strain and can be functionalized for pressure, humidity, and refractive index sensing. Commercial setups for FBG interrogation are based on white-light sources and spectrometer detectors, which are capable of decoding the spectrum of an FBG array. Low-cost spectrometers record the spectrum on a coarse wavelength grid (typically 78–156 pm), whereas wavelength shifts of 1 pm or lower are required by most of the applications. Several algorithms have been presented for detection of small wavelength shift, even with coarse wavelength sampling; most notably, the Karhunen-Loeve Transform (KLT) was demonstrated. In this paper, an improved algorithm based on KLT is proposed, which is capable of further expanding the performances. Simulations show that, reproducing a commercial spectrometer with 156 pm grid, the algorithm estimates wavelength shift with accuracy well below 1 pm. In typical signal-to-noise ratio (SNR) conditions, the root mean square error is 22–220 fm, while the accuracy is 0.22 pm, despite the coarse sampling. Results have been also validated through experimental characterization. The proposed method allows achieving exceptional accuracy in wavelength tracking, beating the picometer level resolution proposed in most commercial and research software, and, due to fast operation (>5 kHz), is compatible also with structural health monitoring and acoustics.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jveUQx
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objectives Greece is one of the leading tobacco-producing countries in European Union, and every year over 19 000 Greeks die from tobacco-at...
-
Objectives Drug interactions, poor adherence to medication and high-risk sexual behaviour may occur in individuals with HIV using recreation...
-
Introduction Multimorbidity (MM) refers to the coexistence of two or more chronic conditions within one person, where no one condition is co...
-
Objective To describe the prevalence and severity of diabetic retinopathy (DR) and sight-threatening DR (STDR) among Chinese adults with dia...
-
Related Articles Three job stress models and their relationship with musculoskeletal pain in blue- and white-collar workers. J Psycho...
-
Abstract Background Mature T-cell and natural killer (NK)-cell lymphomas compose a heterogeneous group of non-Hodgkin lymphomas, and ext...
-
<span class="paragraphSection"><div class="boxTitle">Abstract</div>Masked hypertension (MHT), defined ...
-
Background Hepatitis B virus (HBV) transmission is known to occur through direct contact with infected blood. There has been some suspicion ...
-
In Rwanda, the prevalence of viral hepatitis (HCV) is poorly understood. The current study investigated the prevalence and risk factors of H...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου