Objective: Our primary aim was to determine whether listeners in the following patient groups achieve localization accuracy within the 95th percentile of accuracy shown by younger or older normal-hearing (NH) listeners: (1) hearing impaired with bilateral hearing aids, (2) bimodal cochlear implant (CI), (3) bilateral CI, (4) hearing preservation CI, (5) single-sided deaf CI and (6) combined bilateral CI and bilateral hearing preservation. Design: The listeners included 57 young NH listeners, 12 older NH listeners, 17 listeners fit with hearing aids, 8 bimodal CI listeners, 32 bilateral CI listeners, 8 hearing preservation CI listeners, 13 single-sided deaf CI listeners and 3 listeners with bilateral CIs and bilateral hearing preservation. Sound source localization was assessed in a sound-deadened room with 13 loudspeakers arrayed in a 180-degree arc. Results: The root mean square (rms) error for the NH listeners was 6 degrees. The 95th percentile was 11 degrees. Nine of 16 listeners with bilateral hearing aids achieved scores within the 95th percentile of normal. Only 1 of 64 CI patients achieved a score within that range. Bimodal CI listeners scored at a level near chance, as did the listeners with a single CI or a single NH ear. Listeners with (1) bilateral CIs, (2) hearing preservation CIs, (3) single-sided deaf CIs and (4) both bilateral CIs and bilateral hearing preservation, all showed rms error scores within a similar range (mean scores between 20 and 30 degrees of error). Conclusion: Modern CIs do not restore a normal level of sound source localization for CI listeners with access to sound information from two ears.
Audiol Neurotol 2016;21:127-131
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S90E6Z
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Purpose To test the effects of 4 weeks of unilateral low-load resistance training (LLRT), with and without blood flow restricti...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2juls25 via IFTTT
-
Swedish medical imaging software developer SyntheticMR has received the CE... Read more on AuntMinnieEurope.com Related Reading: Siemen...
-
A phase 1 dose-escalation and expansion study of binimetinib (MEK162), a potent and selective oral MEK1/2 inhibitor British Journal of Canc...
-
ACS Nano DOI: 10.1021/acsnano.6b06114 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kOsUGq via...
-
Long-term clinical outcomes and economic evaluation of the ketogenic diet versus care as usual in children and adolescents with intract...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qoeMDm via IFTTT
-
Relativistic hydrodynamics has been quite successful in explaining the collective behaviour of the QCD matter produced in high energy heavy-...
-
GE Healthcare has introduced Logiq S8 XDclear 2.0, an ultrasound system that... Read more on AuntMinnieEurope.com Related Reading: GE r...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου