Author(s): M.F. Jamaluddin, S. Ghosh, M.P. Waine, M. Tavakoli, J. Amanie, A.D. Murtha, D. Yee, N. Usmani
PurposeThe quality of a low–dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy.Methods and MaterialsIntraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere.ResultsFifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0–2 cm, 95% CI = 0.47–0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2–6). The mean maximum needle velocity was 12.34 cm s−1 (range 4–28 cm s−1) and mean average velocity was 4.76 cm s−1 (range 0.4–17.4 cm s−1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s−1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s−1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907).ConclusionsThis study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvIJxU
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Vol.30 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nItCSB via IFTTT
-
Background Although pneumonia is a leading cause of death in New York City (NYC), limited data exist about the settings in which pneumonia ...
-
Summary We tested whether prophylactic droperidol and ondansetron, in combination with a moderate dose of dexamethasone, were equally effe...
-
by Demin Li, Carol Bentley, Jenna Yates, Maryam Salimi, Jenny Greig, Sarah Wiblin, Tasneem Hassanali, Alison H. Banham Therapeutic monoclon...
-
Vol.69 No.3 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2ltDWNq via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1HDudvw via IFTTT
-
Abstract Dermoscopy has demonstrated clinical benefits in improving early melanoma diagnosis and reducing unnecessary biopsies. Despite th...
-
by Sarah K. Sharman, Bianca N. Islam, Yali Hou, Margaux Usry, Allison Bridges, Nagendra Singh, Subbaramiah Sridhar, Satish Rao, Darren D. Br...
-
ACS Nano DOI: 10.1021/acsnano.6b08567 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oNpdhD via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου