Publication date: Available online 10 February 2017
Source:Brachytherapy
Author(s): M.F. Jamaluddin, S. Ghosh, M.P. Waine, M. Tavakoli, J. Amanie, A.D. Murtha, D. Yee, N. Usmani
PurposeThe quality of a low–dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy.Methods and MaterialsIntraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere.ResultsFifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0–2 cm, 95% CI = 0.47–0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2–6). The mean maximum needle velocity was 12.34 cm s−1 (range 4–28 cm s−1) and mean average velocity was 4.76 cm s−1 (range 0.4–17.4 cm s−1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s−1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s−1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907).ConclusionsThis study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvIJxU
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Point of view: Electrophysiological endpoints differ when comparing the mode of action of highly successful... Point of view: Electrophysiol...
-
Related Articles Feasibility of Brain Atrophy Measurement in Clinical Routine without Prior Standardization of the MRI Protocol:...
-
Background Moyamoya angiopathy (MMA) is characterised by a progressive stenosis of the terminal part of the internal carotid arteries and th...
-
Abstract The core mission of the Early Stage Professionals in Molecular Imaging Sciences (ESPMIS) Interest Group is to help young scientist...
-
Abstract Background A reported penicillin allergy may compromise receipt of recommended antibiotic prophylaxis intended to prevent surgica...
-
In view of the performance requirements (e.g., ride comfort, road holding, and suspension space limitation) for vehicle suspension systems, ...
-
Ravikiran N Pawar, Sambhunath Banerjee, Subhajit Bramha, Shekhar Krishnan, Arpita Bhattacharya, Vaskar Saha, Anupam Chakrapani, Saurabh Bhav...
-
Objectives A major measure of treatment success for drug users undergoing rehabilitation is the ability to enter the workforce and generate ...
-
Context. Despite improvement in pain management and availability of clinical treatment guidelines, patients in Jordan are still suffering fr...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου