Publication date: Available online 10 February 2017
Source:Brachytherapy
Author(s): M.F. Jamaluddin, S. Ghosh, M.P. Waine, M. Tavakoli, J. Amanie, A.D. Murtha, D. Yee, N. Usmani
PurposeThe quality of a low–dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy.Methods and MaterialsIntraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere.ResultsFifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0–2 cm, 95% CI = 0.47–0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2–6). The mean maximum needle velocity was 12.34 cm s−1 (range 4–28 cm s−1) and mean average velocity was 4.76 cm s−1 (range 0.4–17.4 cm s−1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s−1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s−1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907).ConclusionsThis study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kvIJxU
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
This paper proposes an enhanced ant colony optimization with dynamic mutation and ad hoc initialization, ACODM-I, for improving the accuracy...
-
2016-09-24T01-16-18Z Source: International Journal of Research in Medical Sciences Biswajit Majumder, Viral Tandel, Sandip Ghosh, Sharmis...
-
Antibodies, Vol. 7, Pages 6: In-Depth Comparison of Lysine-Based Antibody-Drug Conjugates Prepared on Solid Support Versus in Solution Anti...
-
No large-scale, head-to-head, phase III, randomized, controlled trial with an adequate sample size has investigated the effect of concurrent...
-
Related Articles Long-acting insulin allergy in a diabetic child. Int J Immunopathol Pharmacol. 2017 Apr 01;:394632017700431 Authors...
-
ACS Nano DOI: 10.1021/acsnano.7b02426 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2h1neaG via...
-
JPM, Vol. 8, Pages 5: Acknowledgement to Reviewers of Journal of Personalized Medicine in 2017 Journal of Personalized Medicine doi: 10.339...
-
Accumulating data have indicated that citrus polymethoxyflavones (PMFs) have the ability to affect brain function. In the present study, we ...
-
Hypopharyngeal Cancer Pharmaceutical and Healthcare Pipeline Review, H1 2017 Medgadget (blog) Latest Pharmaceutical and Healthcare di...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου