Publication date: Available online 10 February 2017
Source:Brachytherapy
Author(s): J. DeCunha, C. Janicki, S.A. Enger
PurposeCoronary artery disease involves the deposition of plaque along the walls of a coronary artery leading to narrowed or blocked vessels (stenosis) and is one of the main causes of death in developed countries. Percutaneous transluminal coronary angioplasty (PTCA) is used to reverse stenosis. Restenosis (renarrowing) of the treated vessel is a major complication of PTCA. A metal mesh tube (stent) can be placed inside the vessel to prevent restenosis. Tissue stress incurred during PTCA and stenting can provoke neointimal cell proliferation leading to in-stent restenosis (ISR). Intravascular brachytherapy (IVBT), a form of internal radiotherapy, is used to treat ISR. Renewed interest in IVBT is being expressed as a treatment for patients with ISR in drug-eluting stents. Current treatment planning (TP) of IVBT is extremely limited and assumes human tissue can be approximated by water. The interactions of arterial plaque, guidewires, and the stent have been shown to attenuate radiation significantly but are ignored in TP. Other models have determined the degree of attenuation by each factor in isolation. For the first time, we create a model with several inhomogenities present to determine whether attenuation by multiple inhomogenities combines linearly or if a larger dose reduction than anticipated is realized. We are also able to evaluate a spatial distribution of dose around the source and in arterial walls.Methods and MaterialsA dosimetric analysis of two commercially available IVBT systems was performed in a Monte Carlo–based particle simulation (Geant4). Absorbed dose was calculated using a model of a human coronary artery with a calcified plaque and stent. Dose delivered in water was also calculated to evaluate the accuracy of a water approximation.ResultsDose as a function of θ shows significant variation around IVBT sources. For the Guidant Galileo, dose is reduced by 20% behind stent struts and as much as 66% in a region occluded by the guidewire, plaque, and stent. For the Novoste Beta Cath device, delivered dose is reduced by 19% and 58%, respectively, in the same regions.ConclusionSOur findings show that the water approximation used in clinical practice to calculate dose is inaccurate when inhomogeneities are present. Methods proposed for calculating dose perturbations in IVBT may underestimate the magnitude of dose reduction. Increasing source dwell time seems unlikely to resolve dosimetric issues in IVBT. The effectiveness of currently existing β-emitting devices may be reduced in patients with complex lesions at the treatment site. Investigation of new radioisotopes and off-centering devices should be considered to improve dose outcomes.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kZblDc
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου