Publication date: Available online 15 October 2016
Source:Journal of Biomechanics
Author(s): Marcel M. Rossi, Jacqueline Alderson, Amar El-Sallam, James Dowling, Jeffrey Reinbolt, Cyril J. Donnelly
The aims of this study were to: (i) establish a new criterion method to validate inertia tensor estimates by setting the experimental angular velocity data of an airborne objects as ground truth against simulations run with the estimated tensors, and (ii) test the sensitivity of the simulations to changes in the inertia tensor components. A rigid steel cylinder was covered with reflective kinematic markers and projected through a calibrated motion capture volume. Simulations of the airborne motion were run with two models, using inertia tensor estimated with geometric formula or the compound pendulum technique. The deviation angles between experimental (ground truth) and simulated angular velocity vectors and the root mean squared deviation angle were computed for every simulation. Monte Carlo analyses were performed to assess the sensitivity of simulations to changes in magnitude of principal moments of inertia within ±10% and to changes in orientation of principal axes of inertia within ±10° (of the geometric-based inertia tensor). Root mean squared deviation angles ranged between 2.9° and 4.3° for the inertia tensor estimated geometrically, and between 11.7° and 15.2° for the compound pendulum values. Errors up to 10% in magnitude of principal moments of inertia yielded root mean squared deviation angles ranging between 3.2° and 6.6°, and between 5.5° and 7.9° when lumped with errors of 10° in principal axes of inertia orientation. The proposed technique can effectively validate inertia tensors from novel estimation methods of body segment inertial parameter. Principal axes of inertia orientation should not be neglected when modelling human/animal mechanics.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2eFYbYV
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Despite widespread journal endorsement of reporting guidelines, the poor reproducibility of preclinical research is increasingly under debat...
-
The benefit of the breastfeeding has been well-established. In comparison to partial breast feeding, exclusive breastfeeding has even more b...
-
A report of the Cold Spring Harbor Laboratory/Wellcome Trust Meeting on Engineering Principles in Biology, Cambridge, UK, 14-16 October 2009...
-
Abstract We report here a microscopic tight-binding theoretical study of the dynamic dielectric response of graphene-on-polarizable substr...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
The “new” silk road—the belt and road initiative (BRI)—is China’s grand idea for the 21st century, promising to transform international deve...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου