A specific and reliable HPLC-MS/MS method was developed and validated for the simultaneous determination of protocatechuic acid (PCA), scopolin, (−)-pinoresinol-4,4′-di-O-β-d-glucopyranoside (PDG), acanthoside D, acanthoside B and hyperin in rat plasma for the first time. The analytes were separated on a C18 column (50 × 2.1 mm, 1.8 µm) and a triple-quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source was used for detection. The rat plasma sample was prepared using the protein precipitation procedure. The calibration curves were linear over a concentration range of 1.2–1200.0 ng/mL for PCA, 0.96–960.0 ng/mL for scopolin, 1.12–1120.0 ng/mL for PDG, 1.32–1320.0 ng/mL for acanthoside D, 0.99–990.0 ng/mL for acanthoside B and 1.01–1010.0 ng/mL for hyperin. The intra-day and inter-day precision was less than 11.4% and the relative error (RE) was all within ±15%. The validated method was successfully applied to assess the pharmacokinetics characteristics after the extracts of Acanthopanax sessiliflorus fruits were orally administered to the Sprague-Dawley rat.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2iCJoA1
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου