The normal physiological loads from muscles experienced by the spine are largely unknown due to a lack of data. The aim of this study is to investigate the effects of varying muscle directions on the outcomes predicted from finite element models of human lumbar spine. A nonlinear finite element model of L3–L5 was employed. The force of the erector spinae muscle, the force of the rectus abdominis muscle, follower loads, and upper body weight were applied. The model was fixed in a neural standing position and the direction of the force of the erector spinae muscle and rectus abdominis muscle was varied in three directions. The intradiscal pressure, reaction moments, and intervertebral rotations were calculated. The intradiscal pressure of L4-L5 was 0.56–0.57 MPa, which agrees with the in vivo pressure of 0.5 MPa from the literatures. The models with the erector spinae muscle loaded in anterior-oblique direction showed the smallest reaction moments (less than 0.6 Nm) and intervertebral rotations of L3-L4 and L4-L5 (less than 0.2 degrees). In comparison with loading in the vertical direction and posterior-oblique direction, the erector spinae muscle loaded in the anterior-oblique direction required lower external force or moment to keep the lumbar spine in the neutral position.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2EHPNSj
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Background. Reconstruction of surgical defects following cranial base surgery is challenging. Others have demonstrated that leukocyte-platel...
-
During lytic infection, herpes simplex virus (HSV) DNA is replicated by a mechanism involving DNA recombination. For instance, replication o...
-
IJMS, Vol. 18, Pages 1603: Induction of a Regulatory Phenotype in CD3+ CD4+ HLA-DR+ T Cells after Allogeneic Mixed Lymphocyte Culture; Indic...
-
Dracaena cochinchinensis Lour. is an ethnomedicinally important plant used in traditional Chinese medicine known as dragon’s blood. Excessiv...
-
Taking a slurry reservoir-pipeline-valve system as research object, axial dynamic vibrations of pipe system were induced by coupled hydrauli...
-
Women in Love by . Lawrence. Searchable etext. Discuss with other readers. from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Ino...
-
by Emily M. Zygiel, Karen A. Noren, Marta A. Adamkiewicz, Richard J. Aprile, Heather K. Bowditch, Christine L. Carroll, Maria Abigail S. Cer...
-
Publication date: February 2017 Source: Cryobiology, Volume 74 Author(s): Reza Masoudi, Ahmad Zare Shahneh, Armin Towhidi, Hamid Kohram, A...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου