Publication date: March 2018
Source:Journal of Environmental Radioactivity, Volume 183
Author(s): Andrey Tsapalov, Konstantin Kovler
Mass measurements of indoor radon concentrations have been conducted for about 30 years. In most of the countries, a national reference/action/limit level is adopted, limiting the annual average indoor radon (AAIR) concentration. However, until now, there is no single and generally accepted international protocol for determining the AAIR with a known confidence interval, based on measurements of different durations. Obviously, as the duration of measurements increases, the uncertainty of the AAIR estimation decreases. The lack of the information about the confidence interval of the determined AAIR level does not allow correct comparison with the radon reference level. This greatly complicates development of an effective indoor radon measurement protocol and strategy.The paper proposes a general principle of indoor radon regulation, based on the simple criteria widely used in metrology, and introduces a new parameter – coefficient of temporal radon variation KV(t) that depends on the measurement duration and determines the uncertainty of the AAIR. An algorithm for determining KV(t) based on the results of annual continuous radon monitoring in experimental rooms is proposed. Included are indoor radon activity concentrations and equilibrium equivalent concentration (EEC) of radon progeny. The monitoring was conducted in 10 selected experimental rooms located in 7 buildings, mainly in the Moscow region (Russia), from 2006 to 2013. The experimental and tabulated values of KV(t) and also the values of the coefficient of temporal EEC variation depending on the mode and duration of the measurements were obtained. The recommendations to improve the efficiency and reliability of indoor radon regulation are given. The importance of taking into account the geological factors is discussed. The representativity of the results of the study is estimated and the approach for their verification is proposed.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2E5rQ6x
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
A middle-aged poorly controlled diabetic man developed left-sided orbital and facial swelling several days after extraction of a left upper ...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
-
ACS Nano DOI: 10.1021/acsnano.7b01926 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pOw4te via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου