Publication date: January–February 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 1
Author(s): Elham Hosseinzadeh, Nooshin Banaee, Hassan Ali Nedaie
AimThe aim of this study is to calculate neutron contamination at the presence of circular cones irradiating by 18MV photons using Monte Carlo code.BackgroundSmall photon fields are one of the most useful methods in radiotherapy. One of the techniques for shaping small photon beams is applying circular cones made of lead. Using this method in high energy photon due to neutron contamination is a crucial issue.Materials and methodsInitially, Varian linac producing 18MV photons was simulated and after validating the code, various circular cones were also simulated. Then, the number of neutrons, neutron equivalent dose and absorbed dose per Gy of photon dose were calculated along the central axis.ResultsNumber of neutrons per Gy of photon dose had their maximum value at depth of 2cm and these values for 5, 10, 15, 20 and 30mm circular cones were 9.02, 7.76, 7.61, 6.02 and 5.08 (ncm−2Gy−1), respectively. Neutron equivalent doses per Gy of photon dose had their maximum at the surface of the phantom and these values for mentioned collimators were 1.48, 1.33, 1.31, 1.12 and 1.08 (mSvGy−1), respectively. Neutron absorbed doses had their maximum at the surface of the phantom and these values for mentioned collimators sizes were 103.74, 99.71, 95.77, 81.46 and 78.20 (μGy/Gy), respectively.ConclusionsAs the field size gets smaller, number of neutrons, equivalent and absorbed dose per Gy of photon increase. Also, neutron equivalent dose and absorbed dose are maximum at the surface of phantom and then these values will be decreased.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2mbPfvC
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
Geographic region: Does it matter in cutaneous melanoma of the head and neck? Laryngoscope. 2017 Jun 05;: Authors: Kılıç S, Unsal AA,...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
Objective. We compared the effects of transcranial direct current stimulation at different cortical sites (premotor and motor primary cortex...
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου