Purpose: The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. Methods and Materials: Axial T2-weighted turbo spin echo images and axial DWI echo-planar imaging (EPI) sequences, including single-shot spin-echo (ss-EPI), readout-segmented multishot (rs-EPI), selective excitation-reduced field of view (sTX-EPI), and prototype single-shot technique applying slice-specific shimming (iShim-EPI) sequences, were acquired at 3 T in 10 healthy volunteers (mean age, 26.1 +/- 3.8 years; body mass index, 23.2 +/- 3.0 kg/m2). Two radiologists, blinded to the type of DWI, independently rated DWIs on a 5-point Likert scale regarding subjective image quality features (resolution, demarcation of prostate capsule, zonal anatomy). Interreader agreement was assessed using the intraclass correlation coefficient. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values were assessed separately in the peripheral and transitional zone. For the analysis of geometric distortion, the diameter of the prostate from left to right and from anterior to posterior was measured at the level of the verumontanum on b-1000 DWIs and on T2-weighted turbo spin echo images. Differences were compared using the Wilcoxon rank sum test for qualitative parameters, analysis of variance, and Friedman test for quantitative parameters. A P value of less than 0.05 was considered significant, with correction for multiple comparisons. Results: Interreader agreement was good to excellent (intraclass correlation coefficient, 0.71-0.79) for all qualitative features. Subjective image quality regarding "resolution" was significantly better for ss-EPI than rs-EPI (mean Likert score, 4.25 vs 3.8; P = 0.031) and sTX-EPI (4.25 vs 3.3; P = 0.046) and for iShim-EPI as compared with rs-EPI (4.4 vs 3.8; P = 0.031) and sTX-EPI (4.4 vs 3.3; P = 0.047). There was no significant difference regarding capsule demarcation and zonal anatomy. Signal-to-noise ratio was significantly higher in iShim-EPI than sTX-EPI (SNR +/- standard deviation [SD], 28.13 +/- 8.21 vs 14.96 +/- 2.4; P = 0.015). The ADC values were lower for the peripheral zone in the sTX-EPI than in the ss-EPI (ADC +/- SD, 1002.94 +/- 83.51 vs 1165.05 +/- 115.64; P = 0.013) and the rs-EPI (1002.94 +/- 83.51 vs 1244.40 +/- 89.95; P = 0.0012) and in the transitional zone in the sTX-EPI compared with the rs-EPI (874.50 +/- 200.72 vs 1261.47 +/- 179.23; P = 0.0021). There were no statistically significant differences in geometric distortion between all DWI sequences. Conclusions: Single-shot spin-echo EPI and iShim-EPI showed a tendency toward superior image quality and SNR compared with rs-EPI and sTX-EPI with no significant differences in geometric distortion. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zs3Nxf
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Related Articles Middle ear adenomatous neuroendocrine tumors: a 25-year experience at MD Anderson Cancer Center. Virchows Arch. 2017...
-
Abstract Background The role of thymectomy in the treatment of juvenile myasthenia gravis (JMG) is poorly defined. The objective of this...
-
Biomarker testing is recommended for all patients diagnosed with non–small cell lung cancer. At a minimum, testing should include the mutati...
-
American Thyroid Resarch Grant to Nikita Pozdeyev, MD, PhD, University of Colorado Newswise (press release) The 2016 Research Grant h...
-
A host of new therapies are now available for treating patients with chronic lymphocytic leukemia (CLL) in both the upfront and relapsed or ...
-
In the NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) for Breast Cancer, among adjuvant radiotherapy options for whole-brea...
-
Need APA Citations? Stop wasting time hand-writing your bibliography, sign up for EasyBib Pro Now! Join EasyBib Pro Now from #AlexandrosSf...
-
To link to this poem, put the URL below into your page: <a href=http:///poems/>Song of Myself by Walt Whitman</a> Plain for Prin...
-
ACS Nano DOI: 10.1021/acsnano.7b01995 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o1Fb7w via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου