The total nuclear reaction cross section is calculated considering the cases with and without medium effect by employing Coulomb modified Glauber model (CMGM) for interactions of projectiles 56Fe26, 84Kr36, 132Xe54, 197Au79, and 238U92 with nuclear emulsion detector (NED) nuclei at around 1 GeV per nucleon incident kinetic energy. These calculated nuclear reaction cross sections are correlated with the different target groups of the NED nuclei. The average value of various parameters is also calculated and compared with the corresponding experimental results. The number of shower particles emitted in an interaction is also calculated and showed good agreement with the experimental result. We observed that the total nuclear reaction cross section increases with increasing the target mass number in case of all the considered projectiles. In addition, it is shown that the average value of reaction cross section with nuclear medium effect is in good agreement with the experimental results for projectiles 56Fe, 84Kr, and 132Xe, although results of projectiles 197Au and 238U are not in agreement with the experimental observations. This study sheds some light on the energy dependence of the nuclear reaction cross section.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2yYUt6j
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου