Publication date: Available online 19 January 2018
Source:Academic Radiology
Author(s): Hannes Seuss, Rolf Janka, Matthias Hammon, Alexander Cavallaro, Michael Uder, Peter Dankerl
Rationale and ObjectivesTo evaluate two- and three-dimensional (2D and 3D) image quality of sub-milliSievert (mSv) computed tomography (CT) colonography utilizing a third-generation dual source CT scanner featuring a tin filter.MethodsWe retrospectively evaluated 26 consecutive patients who underwent third-generation dual source CT colonography, nine with the standard-dose clinical-scan protocol (SDP) and 17 with a low-dose protocol (LDP) featuring a tin filter. Radiation dose was evaluated by volume computed tomography dose index (CTDIvol), dose length product (DLP), effective dose (E), and size-specific dose estimate. Objective image quality was evaluated utilizing signal-to-noise ratio (SNR) derived from standardized placed regions of interest on the transverse 2D images and the ratio of SNR/CTDIvol (normalized SNR). Two radiologists in consensus assessed subjective image quality of the virtual 3D images.ResultsThere were no significant differences in subjective image quality (P = .661). All examinations were rated "excellent" or "good" for diagnostic confidence. The mean total for DLP/E was 143.4 ± 29.8 mGy/3.00 ± 0.40 mSv in the SDP and therefore significantly higher than in the LDP with 36.9 ± 8.7 mGy/0.75 ± 0.16 mSv (P < .001). The SNR was 8.9 ± 2.1 in the SDP and 4.9 ± 0.8 in the LDP.ConclusionsThird-generation dual source CT featuring a tin filter enables consistent sub-mSv colonography without substantially impairing image quality.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2mSCB54
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Liver ischemia reperfusion injury (IRI) is inevitable during transplantation and resection and is characterized by hepatocellular injury. Th...
-
Abstract Biodegradable polymer blends of high-molecular-weight poly(3-hydroxybutyrate) (PHB) and poly(lactic acid) (PLA) are not miscible ...
-
IJERPH, Vol. 15, Pages 162: Examining Public Perceptions about Lead in School Drinking Water: A Mixed-Methods Analysis of Twitter Response t...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2uz2El4 via IFTTT
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): T. Pritchard, R. Mrode, M. Coffey, K. Bond, E....
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Radioterapia oncologica, la Cattolica protagonista al Congresso Europeo insalutenews ... l'utilizzo della radioterapia stereotass...
-
Abstract Background Individualized medication reviews may improve our understanding of the distribution of CYP2C19 polymorphisms in ethn...
-
M Mahalakshmi, L Balamurugan, R Madhu, A Ramesh Indian Dermatology Online Journal 2017 8(3):224-225 from #AlexandrosSfakianakis via Al...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου