Prestressed concrete beams of size 150 × 150 × 1000 mm were designed, and two bonded cold-drawn 7 mm steel wires were stressed at 70% UTS under service conditions before concreting. The beams were cast with M40 grade concrete mix with various percentages of chlorides ranging from 0, 1, 2, and 3% by weight of cement and cured for 28 days. After 28 days, the stretching forces were released, the prestressing steel wire was allowed to regain its original length, the tensile stresses were transformed into a compressive stress in the concrete, and the stress corrosion behavior was assessed. Stress corrosion cracking (SCC) is due to the simultaneous action of stress, corrosive media, and material properties. The stress corrosion behavior of ungrouted pretensioned steel was assessed by using various electrochemical techniques such as electrochemical noise, open-circuit potential measurement, AC impedance, and potentiodynamic polarization measurements. The same experiments were conducted for rebars embedded in the concrete beam with various percentages of chlorides ranging from 0, 1, 2, and 3% by weight of chloride. After 30 days of exposure, the beams were tested for their flexural strength measurements to find out the load-bearing capacity.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2n17uFl
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2Gchesc via IFTTT
-
Abstract Determining the cause of unexplained death in all age groups, including infants, is a priority in forensic medicine. The triple r...
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2BeOBVJ via IFTTT
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2rxuJIO via IFTTT
-
Abstract In this paper we present the study of a skull belonging to a young male from the Italian Bronze Age showing three perimortem inju...
-
Abstract To measure integral doses in image-guided radiation therapy, we developed an integral condenser dosimeter comprising a disposable...
-
Objectives. To assess the association between short-term postoperative cognitive dysfuction (POCD) and inflammtory response in patients unde...
-
Abstract Layer-by-layer (LbL) dip coating, accompanying with the use of micelle structure, allows hydrophobic molecules to be coated on me...
-
This paper presents an adaptive multiuser transceiver scheme for DS-CDMA systems in which pilot symbols are added to users’ data to estimate...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου