This study evaluated the influence of reinforcement fiber type and microsilica content on the performance of latex-modified fiber-reinforced roller-compacted rapid-hardening cement concrete (LMFRCRSC) for a concrete pavement emergency repair. Experimental variables were the microsilica substitution ratio (1, 2, 3, and 4%), and the reinforcement fiber (jute versus macrosynthetic fiber). In the tests, compressive, flexural, and splitting tensile strength; chloride ion penetration resistance; and abrasion resistance were assessed. From the compressive and flexural strength tests with microsilica substitution, the 4-hour curing strength decreased as the microsilica substitution ratio increased. From the chloride ion penetration test, as the microsilica substitution ratio increased, chloride ion penetration decreased. The abrasion resistances increased with the substitution ratio of microsilica increase. Based on these test results, microsilica at a substitution ratio of 3% or less and macrosynthetic fiber as the reinforcement improved the performance of LMFRCRSC for a concrete pavement emergency repair and satisfied all of the target strength requirements.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2F1QzJw
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2BeOBVJ via IFTTT
-
Abstract Determining the cause of unexplained death in all age groups, including infants, is a priority in forensic medicine. The triple r...
-
Movies to watch this week at the cinema: Sully, Moana, The Unknown Girl, Chi-Raq, Bleed for This, more... By Total Film Staff from #Alexan...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o3fxRd via IFTTT
-
The last few days we see this error message in our website too much: Timeout expired. The timeout period elapsed prior to obtaining a connec...
-
Patients who undergo endovascular repair of aortic aneurysms (EVAR) require life-long surveillance because complications including, in parti...
-
Abstract To measure integral doses in image-guided radiation therapy, we developed an integral condenser dosimeter comprising a disposable...
-
Share | © , 2003-2017, #4## | About | 2257 | DMCA | Privacy Policy | Terms of Use | News | Advanced Search | Advertisers | Feedback from #...
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2ErcmxL via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου