The CMOS Monolithic Active Pixel Sensor (MAPS) for the International Linear Collider (ILC) vertex detector (VXD) expresses stringent requirements on their analog readout electronics, specifically on the analog-to-digital converter (ADC). This paper concerns designing and optimizing a new architecture of a low power, high speed, and small-area 4-bit column-parallel ADC Flash. Later in this study, we propose to interpose an S/H block in the converter. This integration of S/H block increases the sensitiveness of the converter to the very small amplitude of the input signal from the sensor and provides a sufficient time to the converter to be able to code the input signal. This ADC is developed in 0.18 μm CMOS process with a pixel pitch of 35 μm. The proposed ADC responds to the constraints of power dissipation, size, and speed for the MAPS composed of a matrix of 64 rows and 48 columns where each column ADC covers a small area of 35 × 336.76 μm2. The proposed ADC consumes low power at a 1.8 V supply and 100 MS/s sampling rate with dynamic range of 125 mV. Its DNL and INL are 0.0812/−0.0787 LSB and 0.0811/−0.0787 LSB, respectively. Furthermore, this ADC achieves a high speed more than 5 GHz.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jrqngY
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nL9dMr via IFTTT
-
Vol.30 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nItCSB via IFTTT
-
Background Although pneumonia is a leading cause of death in New York City (NYC), limited data exist about the settings in which pneumonia ...
-
Summary We tested whether prophylactic droperidol and ondansetron, in combination with a moderate dose of dexamethasone, were equally effe...
-
by Demin Li, Carol Bentley, Jenna Yates, Maryam Salimi, Jenny Greig, Sarah Wiblin, Tasneem Hassanali, Alison H. Banham Therapeutic monoclon...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1HDudvw via IFTTT
-
ACS Nano DOI: 10.1021/acsnano.6b08567 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oNpdhD via...
-
Vol.69 No.3 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2ltDWNq via IFTTT
-
Abstract Dermoscopy has demonstrated clinical benefits in improving early melanoma diagnosis and reducing unnecessary biopsies. Despite th...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου