The CMOS Monolithic Active Pixel Sensor (MAPS) for the International Linear Collider (ILC) vertex detector (VXD) expresses stringent requirements on their analog readout electronics, specifically on the analog-to-digital converter (ADC). This paper concerns designing and optimizing a new architecture of a low power, high speed, and small-area 4-bit column-parallel ADC Flash. Later in this study, we propose to interpose an S/H block in the converter. This integration of S/H block increases the sensitiveness of the converter to the very small amplitude of the input signal from the sensor and provides a sufficient time to the converter to be able to code the input signal. This ADC is developed in 0.18 μm CMOS process with a pixel pitch of 35 μm. The proposed ADC responds to the constraints of power dissipation, size, and speed for the MAPS composed of a matrix of 64 rows and 48 columns where each column ADC covers a small area of 35 × 336.76 μm2. The proposed ADC consumes low power at a 1.8 V supply and 100 MS/s sampling rate with dynamic range of 125 mV. Its DNL and INL are 0.0812/−0.0787 LSB and 0.0811/−0.0787 LSB, respectively. Furthermore, this ADC achieves a high speed more than 5 GHz.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jrqngY
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Caring for Patients with Physical Disabilities: Assessment of an Innovative Spinal Cord Injury Session that Addresses an Educational Gap Des...
-
http://orl-agios.blogspot.com/2017/06/the-preclinical-anticancer-effect-of.html Flavonoids present in foods were considered non-absorbable b...
-
World Community; and Remarks on our Own Behalf Models of Anticipation Within the Responsible Research and Innovation Framework: the Two RRI ...
-
Vol.31 No.5 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1k8FKtW via IFTTT
-
Radioterapia oncologica, la Cattolica protagonista al Congresso Europeo insalutenews ... l'utilizzo della radioterapia stereotass...
-
Publication date: Available online 24 December 2017 Source: European Journal of Radiology Author(s): Wenbin Jiang, Hongwei Xue, Qinqin W...
-
Related Articles Promoting the Inclusion of Lung Volumes in the Reversibility Evaluation-Reply. Respir Care. 2017 Feb;62(2):256 Auth...
-
We report an unusual case of a strangulated internal hernia resulting from a right paraduodenal fossa hernia (PDH) in the context of bowel m...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου