Purpose The aim of this study was to investigate whether the detection of foreign bodies can be improved using dark-field and phase-contrast radiography compared with conventional (transmission) radiographs. Materials and Methods Experiments were performed using ex vivo pig paws, which were prepared with differently sized foreign bodies of metal, wood, and glass (n = 10 each). Paws without foreign bodies served as controls (n = 30). All images were acquired using an experimental grating-based large object radiography system. Five blinded readers (second- to fourth-year radiology residents) were asked to assess the presence or absence of any foreign body. Sensitivity and specificity for the detection of metal, wood, glass, and any foreign body were calculated and compared using McNemar test and generalized linear mixed models. Results Sensitivity for the detection of metal foreign bodies was 100% for all readers and image combinations. The sensitivity for the detection of wooden foreign bodies increased from 2% for transmission images to 78% when dark-field images were added (P
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2nMPEWW
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου