Publication date: September 2018
Source:Journal of Environmental Radioactivity, Volume 189
Author(s): V. Moreno, J. Bach, M. Zarroca, Ll. Font, C. Roqué, R. Linares
Radon levels in the soil and groundwater in the North Maladeta Fault area (located in the Aran Valley sector, Central Pyrenees) are analysed from both geological and radiation protection perspectives. This area is characterized by the presence of two important normal faults: the North Maladeta fault (NMF) and the Tredós Fault (TF). Two primary aspects make this study interesting: (i) the NMF shows geomorphic evidence of neotectonic activity and (ii) the presence of a thermal spa, Banhs de Tredós, which exploits one of the several natural springs of the area and needs to be evaluated for radiation dosing from radon according to the European regulation on basic safety standards for protection against ionizing radiation. The average soil radon and thoron concentrations along a profile perpendicular to the two normal faults — 22 ± 3 kBq·m−3 and 34 ± 3 kBq·m−3, respectively — are not high and can be compared to the radionuclide content of the granitic rocks of the area, 25 ± 4 Bq·kg−1 for 226Ra and 38 ± 2 Bq·kg−1 for 224Ra. However, the hypothesis that the normal faults are still active is supported by the presence of anomalies in both the soil radon and thoron levels that are unlikely to be of local origin together with the presence of similar anomalies in CO2 fluxes and the fact that the highest groundwater radon values are located close to the normal faults. Additionally, groundwater 222Rn data have complemented the hydrochemistry data, enabling researchers to better distinguish between water pathways in the granitic and non-granitic aquifers. Indoor radon levels in the spa vary within a wide range, [7–1664] Bq·m−3 because the groundwater used in the treatment rooms is the primary source of radon in the air. Tap water radon levels inside the spa present an average value of 50 ± 8 kBq·m−3, which does not exceed the level stipulated by the Spanish Nuclear Safety Council (CSN) of 100 kBq·m−3 for water used for human consumption. This finding implies that even relatively low radon concentration values in water can constitute a relevant indoor radon source when the transfer from water to indoor air is efficient. The estimated effective dose range of values for a spa worker due to radon inhalation is [1–9] mSv·y−1. The use of annual averaged radon concentration values may significantly underestimate the dose in these situations; therefore, a detailed dynamic study must be performed by considering the time that the workers spend in the spa.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2FOpqxC
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Brain Networks are Independently Modulated by Donepezil, Sleep, and Sleep Deprivation. Brain Topogr. 2017 Nov 23;: Authors: Wirsich J...
-
Abstract Diphenylarsinic acid (DPAA) is an organic arsenic compound used for the synthesis of chemical weapons. We previously found that th...
-
To evaluate the effect of Recurrence Score® results (RS; Oncotype DX® multigene assay ODX) on treatment recommendations by Swiss multidiscip...
-
Pugazhenthan Thangaraju, Sajitha Venkatesan, MK Showkath Ali Indian Journal of Community Medicine 2018 43(1):58-59 from #AlexandrosSfa...
-
IJMS, Vol. 18, Pages 1601: Updated Insight into the Physiological and Pathological Roles of the Retromer Complex International Journal of M...
-
2016-10-20T01-26-57Z Source: International Journal of Advances in Medicine Sifna Tahir, Altaf Ahmad Mir, Abdul Hameed. Background: Post...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου