Source:Journal of Environmental Radioactivity, Volume 188
Author(s): Dominik Grządziel, Krzysztof Kozak, Jadwiga Mazur, Mariusz Mroczek
ISOCS (In Situ Counting Object System) from Canberra is applied in laboratory for creating efficiency calibrations of good quality without using radioactive standards. Besides of typical sample containers used in laboratory, ISOSC system also allows modelling containers and objects of almost any shape and elemental composition.The study was based on gamma spectrometry with HPGe semiconductor detector with electronics and software spectrum analysis GENIE 2000 + ISOCS. Measuring set is equipped with portable shield system with set of collimators ISOCS Shield Systems Model ISOXSHLD from Canberra. This shielding system provides attenuation of gamma background radiation with average value 33 (for gamma energies from 186 keV to 2615.5 keV).The portable shield system can be used for low-background laboratory measurements. For this purpose a measuring vessel of new geometry was constructed: the polystyrene cylinder with a height of 40 mm and a diameter of 70 mm. The efficiency calibration for this container was performed using both ISOCS system and classical calibration standard in the same geometry. In order to verify the correctness of performed calibration procedures, the measurements of radioactive standard CBSS 2 were made. The results of both calibrations were compared with the data from the standard certificate. Satisfactory agreement was achieved. Mean percentage difference between results from ISOCS calibration compared to reference values is 6% for all isotopes activities in CBSS 2 standard.The set of collimators was used to develop efficiency calibration for in situ measurements of the soil surface. Test measurements were carried out at the area of the Institute of Nuclear Physics Polish Academy of Sciences in Kraków, Poland (IFJ PAN). Two measurement methods were compared: in situ and laboratory gamma spectroscopy. The obtained average results (from all 10 measuring points) are consistent within the range of measurement uncertainty.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2yEKwv8
Δευτέρα 19 Μαρτίου 2018
Application of ISOCS system in the laboratory efficiency calibration
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract T cell immunoglobulin and mucin domain 3 (Tim-3) is a critical regulatory molecule found on activated Th1 cells, exhausted CD8 + ...
-
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that pub...
-
CFS, also known as ME, may be caused by the body switching from fully breaking down carbohydrates to using other energy sources, bringing o...
-
Study of Sharp Corner Cutting In Wire EDM Thesis submitted in accordance with The test specimens have been cut by using different wire-cut E...
-
Visit this site dedicated to Valentine from 100 Valentine Poems for your special person. Famous Valentine Poems from the Worlds greatest Poe...
-
You could soon get an even more immersive VR experience thanks to the Ambiotherm plug in, which exposes you to the elements of your virtual...
-
Planta Med DOI: 10.1055/s-0043-106050 Glucose homeostasis is maintained by antagonistic hormones such as insulin and glucagon as well as ...
-
Cancerous tumours are voracious. Once they have consumed all the oxygen and nutrients in the original tumour site, the cancer cells travel t...
-
Publication date: 15 February 2017 Source: Experimental Cell Research, Volume 351, Issue 2 from #AlexandrosSfakianakis via Alexandros...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου