Publication date: Available online 19 February 2018
Source:Radiotherapy and Oncology
Author(s): Jung-Ha Kim, Doan T. Nguyen, Jeremy T. Booth, Chen-Yu Huang, Todsaporn Fuangrod, Per Poulsen, Ricky O'Brien, Vincent Caillet, Thomas Eade, Andrew Kneebone, Paul Keall
Background and purposeTo perform a quantitative analysis of the accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom (6DoF) prostate motion measurements during treatments.Material and methodsReal-time 6DoF prostate motion was acquired using KIM for 14 prostate cancer patients (377 fractions). KIM outputs the 6DoF prostate motion, combining 3D translation and 3D rotational motion information relative to its planning position. The corresponding groundtruth target motion was obtained post-treatment based on kV/MV triangulation. The accuracy and precision of the 6DoF KIM motion estimates were calculated as the mean and standard deviation differences compared with the ground-truth.ResultsThe accuracy ± precision of real-time 6DoF KIM−measured prostate motion were 0.2 ± 1.3° for rotations and 0.1 ± 0.5 mm for translations, respectively. The magnitude of KIM-measured motion was well-correlated with the magnitude of ground-truth motion resulting in Pearson correlation coefficients of ≥0.88 in all DoF.ConclusionsThe results demonstrate that KIM is capable of providing the real-time 6DoF prostate target motion during patient treatments with an accuracy ± precision of within 0.2 ± 1.3° and 0.1 ± 0.5 mm for rotation and translation, respectively. As KIM only requires a single X-ray imager, which is available on most modern cancer radiotherapy devices, there is potential for widespread adoption of this technology.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2ERp9JB
Δευτέρα 19 Φεβρουαρίου 2018
The accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου