The physical constraints of ever-shrinking CMOS transistors are rapidly approaching atomistic and quantum mechanical limits. Therefore, research is now directed towards the development of nanoscale devices that could work efficiently in the sub-10 nm regime. This coupled with the fact that recent design trend for analog signal processing applications is moving towards current-mode circuits which offer lower voltage swings, higher bandwidth, and better signal linearity is the motivation for this work. A digitally controlled DVCC has been realized using CNFETs. This work exploited the CNFET’s parameters like chirality, pitch, and numbers of CNTs to perform the digital control operation. The circuit has minimum number of transistors and can control the output current digitally. A similar CMOS circuit with 32 nm CMOS parameters was also simulated and compared. The result shows that CMOS-based circuit requires 418.6 μW while CNFET-based circuit consumes 352.1 μW only. Further, the proposed circuit is used to realize a CNFET-based instrumentation amplifier with digitally programmable gain. The amplifier has a CMRR of 100 dB and ICMR equal to 0.806 V. The 3 dB bandwidth of the amplifier is 11.78 GHz which is suitable for the applications like navigation, radar instrumentation, and high-frequency signal amplification and conditioning.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2reSx75
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
Geographic region: Does it matter in cutaneous melanoma of the head and neck? Laryngoscope. 2017 Jun 05;: Authors: Kılıç S, Unsal AA,...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
-
ACS Nano DOI: 10.1021/acsnano.7b01926 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pOw4te via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου