Background. Microscopic analysis of stained blood smear is the most suitable method of malaria diagnosis. However, gaps were observed among clinical laboratory professionals in microscopic diagnosis of malaria. Methods. A cross-sectional study was conducted in December 2015 among 46 laboratory professionals. Data was collected via on-site assessment and panel testing. The slide panel testing was composed of positive and negative slides. The kappa score was used to estimate the agreement between participants and reference reader. Results. The overall agreement between the study participants and the reference reader in malaria detection was 79% (kappa = 0.62). Participating in refresher training on malaria microscopy (Adjusted Odds Ratio (AOR = 7, CI = 1.5–36.3)) and malaria epidemic investigation (AOR = 4.1 CI = 1.1–14.5) had statistical significant association with detection rate of malaria parasites. Conclusion. Laboratory professionals showed low performance in malaria microscopy. Most of the study participants were graded “in-training” in laboratory diagnosis of malaria.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2BJJX4w
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Sensory Topography of Oral Structures. JAMA Otolaryngol Head Neck Surg. 2016 Sep 29; Authors: Bearelly S, Cheung SW Abstract Import...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου