Publication date: Available online 23 December 2017
Source:European Journal of Radiology
Author(s): Mischa Woisetschläger, Anna Spångeus
BackgroundOsteoporosis is a common but underdiagnosed and undertreated disease causing severe morbidity and economic burden. The gold standard for detection of osteoporosis is DXA (dual energy x-ray absorptiometry), which is a dedicated examination for osteoporosis. Dual energy CT (DECT) examinations are increasingly used in daily routine for a wide variety of diagnoses. In the present study, we wanted to examine whether vBMD (volume bone mass density) could be evaluated as a side product in non-contrast as well as contrast phases as well as to evaluate a correction model taking known shortcomings for DXA into account.MethodsA total of 20 patients, i.e. 79 vertebrae (one excluded due to vertebral fracture), mean age 71 years (range 43–85) with a mean BMI (body mass index) of 26 (range 17–33) were examined with both abdominal/pelvic DECT as well as DXA. Furthermore, aortic calcium was measured as well as the presence of osteoarthritis of the spine (OAS) and osteoarthritis in facet joints (OAF) with a 5-grade scaling system.ResultsA significant correlation was found between DXA BMD and vBMD from DECT with no contrast (WNC) (r = 0.424, p = 0.001), and with venous contrast (WVC) (r = 0.402, p < 0.001), but no significant correlation was found with arterial contrast (WAC). Using multivariate linear regression with DXA BMD as dependent, two models were created combining DECT WNC, aortic calciumscore (ACS), OAS and BMI yielding an R2 = 0.616 (model 1) and replacement of WNC to WVC a R2 = 0.612 (model 2). The Pearson correlation between DXA and predictive DXA BMD value of model 1 was r = 0.785 (p < 0.001) and model 2 r = 0.782 (p < 0.001).ConclusionThere is a correlation between DXA BMD and DECT in non-contrast and venous contrast scans but not in arterial scans. The correlation is further improved by quantifying the degree of different confounding factors (osteoarthritis of the spine, body mass index and aortic calcium score) and taking these into account in an explanatory model. Future software solutions with DECT data as input data might be able to automatically measure the BMD in the trabecular bone as well as measuring the confounding factors automatically in order to obtain spinal DXA comparable BMD values.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2CbPwc1
Τετάρτη 27 Δεκεμβρίου 2017
Model for improved correlation of BMD values between abdominal routine Dual energy CT data and DXA scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Family: Know the drill New Straits Times Online One of my sons had this so often that his tonsils were removed. ... However, for som...
-
UM-Chor1: establishment and characterization of the first validated clival chordoma cell line. J Neurosurg. 2017 Apr 21;:1-9 Authors:...
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): R.E. Vibart, M. Tavendale, D. Otter, B.H. Schw...
-
Abstract Cerebral and systemic organ microvascular pathologies coexist with human Alzheimer’s disease (AD) neuropathology. In this study, w...
-
Related Articles Developmental control of macrophage function. Curr Opin Immunol. 2017 Dec 13;50:64-74 Authors: Bonnardel J, Guillia...
-
Description A Caucasian boy aged 5 years presented with acute onset of a non-tender, palpable purpuric rash to his lower limbs, preceded by ...
-
Purpose. Sinonasal malignant mucosal melanoma is a rare, aggressive tumour. Nasal obstruction and epistaxis are the most commonly reported s...
-
Abstract Conquering immunosuppression in tumor microenvironments is crucial for effective cancer immunotherapy. It is well known that inte...
-
Abstract: Epidermolytic ichthyosis (EI) is a rare disorder of cornification caused by mutations in KRT1 and KRT10, encoding two suprabasal e...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου