Publication date: Available online 23 December 2017
Source:European Journal of Radiology
Author(s): Mischa Woisetschläger, Anna Spångeus
BackgroundOsteoporosis is a common but underdiagnosed and undertreated disease causing severe morbidity and economic burden. The gold standard for detection of osteoporosis is DXA (dual energy x-ray absorptiometry), which is a dedicated examination for osteoporosis. Dual energy CT (DECT) examinations are increasingly used in daily routine for a wide variety of diagnoses. In the present study, we wanted to examine whether vBMD (volume bone mass density) could be evaluated as a side product in non-contrast as well as contrast phases as well as to evaluate a correction model taking known shortcomings for DXA into account.MethodsA total of 20 patients, i.e. 79 vertebrae (one excluded due to vertebral fracture), mean age 71 years (range 43–85) with a mean BMI (body mass index) of 26 (range 17–33) were examined with both abdominal/pelvic DECT as well as DXA. Furthermore, aortic calcium was measured as well as the presence of osteoarthritis of the spine (OAS) and osteoarthritis in facet joints (OAF) with a 5-grade scaling system.ResultsA significant correlation was found between DXA BMD and vBMD from DECT with no contrast (WNC) (r = 0.424, p = 0.001), and with venous contrast (WVC) (r = 0.402, p < 0.001), but no significant correlation was found with arterial contrast (WAC). Using multivariate linear regression with DXA BMD as dependent, two models were created combining DECT WNC, aortic calciumscore (ACS), OAS and BMI yielding an R2 = 0.616 (model 1) and replacement of WNC to WVC a R2 = 0.612 (model 2). The Pearson correlation between DXA and predictive DXA BMD value of model 1 was r = 0.785 (p < 0.001) and model 2 r = 0.782 (p < 0.001).ConclusionThere is a correlation between DXA BMD and DECT in non-contrast and venous contrast scans but not in arterial scans. The correlation is further improved by quantifying the degree of different confounding factors (osteoarthritis of the spine, body mass index and aortic calcium score) and taking these into account in an explanatory model. Future software solutions with DECT data as input data might be able to automatically measure the BMD in the trabecular bone as well as measuring the confounding factors automatically in order to obtain spinal DXA comparable BMD values.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2CbPwc1
Τετάρτη 27 Δεκεμβρίου 2017
Model for improved correlation of BMD values between abdominal routine Dual energy CT data and DXA scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
CBN News Cancer Took Most of His Tongue, but This Pastor Is Still Singing ... CBN News A youth pastor in San Diego, California is not ...
-
A middle-aged poorly controlled diabetic man developed left-sided orbital and facial swelling several days after extraction of a left upper ...
-
Related Articles Audiologic and radiologic findings in cochlear hypoplasia. Auris Nasus Larynx. 2017 Jan 10;: Authors: Cinar BC, Bat...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου