Multiplex bead-based immunoassays are used to measure concentrations of several analytes simultaneously. These assays include control standard curves (SC) to reduce between-plate variability and normalize quantitation of analytes of biological samples. Suboptimal calibration might result in large random error and decreased number of samples with analyte concentrations within the limits of quantification. Suboptimal calibration may be a consequence of poor fitness of the functions used for the SC, the treatment of the background noise and the method used to estimate the limits of quantification. Currently assessment of fitness of curves is largely dependent on operator and that may add additional error. Moreover, there is no software to automate data managing and quality control. In this article we present a R package, drLumi, with functions for managing data, calibrating assays and performing quality control. To optimize the assay the package implements: i) three dose-response functions, ii) four approaches for treating background noise and iii) three methods for estimating limits of quantifications. Other implemented functions are focused on the quality control of the fitted standard curve: detection of outliers, estimation of the confidence or prediction interval, and estimation of summary statistics. With demonstration purpose, we apply the software to 30 cytokines, chemokines and growth factors measured in a multiplex bead-based immunoassay in a study aiming to measure correlates of risk or protection from malaria of the RTS,S malaria vaccine nested in the Phase 3 randomized controlled trial of this vaccine.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2AGtOd3
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
New analysis shows that some of these amazing flying beasts were far more formidable than we'd ever thought before... -- Read more on...
-
Do you speak NHS?Oh, yes: you don’t get far in the health service without being able to generate a seamless flow of the right words, if only...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oDLxf6 via IFTTT
-
The government has announced its intention to make sex and relationships education (SRE) statutory in all secondary schools, and to make rel...
-
Abstract Purpose The aim of this study is to evaluate the feasibility of a telehealthcare application for operable lung cancer (OLC) patie...
-
Bristol-Myers Squibb Co Cancer Drug Cost Comes Under Fire In U.K. StockNews.com (blog) NICE noted the evidence that nivolumab can ext...
-
Abstract Background Medical therapy efficacy remains controversial in stricturing Crohn's disease. Cross-sectional imaging, especial...
-
Abstract The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o3hqws via IFTTT
-
Abstract Patients with sulfite oxidase (SO) deficiency present severe brain abnormalities, whose pathophysiology is not yet elucidated. We...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου