This paper studies the vertical dynamic properties of a beam-like bridge attached with standing people. A purpose-built lively bridge was constructed. Model properties of the empty structure are obtained using ambient vibration testing method. Experimental tests of the bridge attached with standing people were also conducted covering a variety of densities of occupants and different postures. The considerable number of participants and repetitions makes it possible to take into account inter- and intrasubject variability. To illustrate the variations of dynamic properties of the structure, a mathematic model of standing people-structure interaction system is developed employing the single degree-of-freedom (SDOF) human body model. It is shown that the model developed herein can effectively illustrate the experimental observations. Based on the model, the effect of damping and natural frequency of the human body on dynamic properties of the occupied structure is scrutinized. Results show that the modal properties of the human body contribute remarkably to the structural damping but little to the structural natural frequencies.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2ALqXPq
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου